background image

7

Reminder:   

Software is installed completed. “Get DataLog’s Identifier” shows as below, then press 

SETTING

 button to 

enter Logger setting from the tool bar. 

If logger is not plugged in USB port, the warning message “Reminder: Data Logger is not plugged in USB 
port!” shows as below. Replug the USB to PC, and restart the software, if the warning message shows again, 
follow NOTE1 below to find the correct COM port.   

NOTE 1: 

If software message box show as above, follow the steps below: 
a)  Click “My computer” “Content” in hardware content, click “Device manager” to find the listed (COMx) 

under ports (COM % LPT as below. If you may find “Prolific USB- to-Seriral Comm port, it means the 
logger is connected to computer properly. 

b)  Remember the Comm port number and go back to software 
c)  Click “Setting” “Comm port” select the port number as you see from step1, then press OK button.

Logger Setting: 

2

c

i

P

1

c

i

P

Pic 3 

8

BASIC(Pic 1): 
1: ID setting 

Maximum 20 characters, name your logger press OK button to confirm 

Please type in capital. Space is unacceptable. 

2: Current Date/Time 

Clock setting, the system automatically shows current date and time of your pc. Press OK to confirm.
(Note: Schedule date & time refer to current PC date and time) 

Please click OK to sync the meter's date and time every time. 

ALARM & SENSOR (Pic 2):

1.  Please set O

low alarm manually.(check it to sync to meter) 

2.  The parameter sensors are default. 

SETTING (Pic 3) : 

1.  Set sample point (K=1,000 multiple basis within total memory points). 
2.  Set sample rate, start mode to record: 

Select “hour (1~6), “minute (0~59)”, “second (0~59)” time interval. 

Select 5 start modes from: 

l

 Immediately 

l

 Schedule 

l

 Real-time (PC is always connected with the logger) 

l

 Key start/off (Start/stop recording by long pressing 

BKLT

 button) 

l

 Roll-over (when memory are full, logger covers the earliest memory automatically) 

3. 

Select Unit : Select Temperature unit °C/°F for recording, press OK to confirm

LOGGER STATUS 

Before download data, press LOGGER status to show ID, Records, Sample rate, Unit. 

NOTE:

 Once Download button is pressed, meter won’t keep recording. 

l

Schedule start mode: 

Select the date and time meter will start recording. The recording start time is software's current time not 
meters’. Please set up the current time correctly. (Follow the format in software: D-M-Y, H: M: S) 

l

Real-time start mode: 

After set start mode at real-time, datalogger starts login records. While recording, the green fan at left 
corner is flashing. (Meter should be connected with pc all the time, under this mode.) In real-time mode, it 
shows “

STOP

” button instead of “

DOWNLOAD

” at the right corner. Press 

STOP

 to stop real-time 

recording. 

Before exit software, data has to be downloaded, otherwise, data will be cleaned.

l

Key-start/off mode: 

Select the mode to record once long press 

BKLT

 button, long press 

BKLT

 button again to stop recording. 

Data has to be downloaded before next key-start. 

NOTE: 

After key off the recording, the data has to download before next recording start. 

l

Roll-over mode: 

After Roll-over mode is selected. Press OK, the meter will start to record. When the data is full, it will cover 

Summary of Contents for HHAQ-104

Page 1: ...cifications without notice WARNING These products are not designed for use in and should not be used for human applications Servicing North America U S A Omega Engineering Inc One Omega Drive P O Box...

Page 2: ...ifications without notice WARNING These products are not designed for use in and should not be used for human applications Servicing North America U S A Omega Engineering Inc One Omega Drive P O Box 4...

Page 3: ...32 T mm Probe size 145 H x 33 W x 33 T mm PU cable 657mm 20mm Length Cable Tube Approx 1Meter coil cable 30cm soft tube Power AAA batteries x 6 pcs or AC DC adaptor 2 ATTENTION Do not attempt to open...

Page 4: ...T mm Probe size 145 H x 33 W x 33 T mm PU cable 657mm 20mm Length Cable Tube Approx 1Meter coil cable 30cm so tube Power AAA ba eries x 6 pcs or AC DC adaptor 2 ATTENTION Do not attempt to open the m...

Page 5: ...t is stable enough or you don t operation in few minutes you may turn off the fan by short pressing SET button MAX MIN Press the button to review maximum or minimum readings since powered on To clear...

Page 6: ...t is stable enough or you don t operation in few minutes you may turn off the fan by short pressing SET button MAX MIN Press the button to review maximum or minimum readings since powered on To clear...

Page 7: ...lover or Key start mode to record data you don t have to reset up each parameter or setting from PC after downloading i e After download stored data to PC meter may long press BKLT button to repeat re...

Page 8: ...lover or Key start mode to record data you don t have to reset up each parameter or setting from PC after downloading i e After download stored data to PC meter may long press BKLT button to repeat re...

Page 9: ...ple basis within total memory points 2 Set sample rate start mode to record Select hour 1 6 minute 0 59 second 0 59 time interval Select 5 start modes from l Immediately l Schedule l Real time PC is a...

Page 10: ...ple basis within total memory points 2 Set sample rate start mode to record Select hour 1 6 minute 0 59 second 0 59 time interval Select 5 start modes from l Immediately l Schedule l Real time PC is a...

Page 11: ...AAA x 6 pcs or AC DC adaptor and check again Or sensor is damaged Normally LED on probe turns red Q2 Readings are freeze A2 Make sure you are using HOLD function otherwise make sure the cable is well...

Page 12: ...AAA x 6 pcs or AC DC adaptor and check again Or sensor is damaged Normally LED on probe turns red Q2 Readings are freeze A2 Make sure you are using HOLD function otherwise make sure the cable is well...

Page 13: ...OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR P...

Page 14: ...OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR P...

Reviews: