 FP90 Series Flow Transmitter Instructions

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. 
OMEGA is constantly pursuing certifi cation of its products to the European New Approach Directives. 
OMEGA will add the CE mark to every appropriate device upon certifi cation.

The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts 
no liability for any errors it contains, and reserves the right to alter specifi cations without notice.
WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.

Servicing North America:

USA:

                          

One Omega Drive, P.O. Box 4047

ISO 9001 Certi ed                

Stamford CT 06907-0047

                                           TEL: (203) 359-1660                                   FAX: (203) 359-7700
                                           e-mail: [email protected]

Canada:                     

976 Bergar

                                           Laval (Quebec) H7L 5A1
                                           TEL: (514) 856-6928                                     FAX: (514) 856-6886
                                           e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada:

 

Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA

®

                                           Customer Service: 1-800-622-2378 / 1-800-622-BEST

®

                                           Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN

®

                                           TELEX: 996404   EASYLINK: 62968934   CABLE: OMEGA

Mexico:

                    

En Español: (001) 203-359-7803                e-mail: [email protected]

                                           FAX: (001) 203-359-7807                                         [email protected]

Servicing Europe:

Benelux:

                  

 Postbus 8034, 1180 LA Amstelveen, The Netherlands

                                           TEL: +31 (0)20 3472121                              FAX: +31 (0)20 6434643
                                           Toll Free in Benelux: 0800 0993344
                                           e-mail: [email protected]

Czech Republic:      

Rudé arm

.

dy 1868, 733 01 Karvin

.

 8

                                           TEL: +420 (0)59 6311899                           FAX: +420 (0)59 6311114
                                           Toll Free: 0800-1-66342

                          

e-mail: [email protected]

France:                       

11, rue Jacques Cartier, 78280 Guyancourt, France

                                           TEL: +33 (0)1 61 37 29 00                            FAX: +33 (0)1 30 57 54 27
                                           Toll Free in France: 0800 466 342
                                           e-mail: [email protected]

Germany/Austria: 

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

                                           TEL: +49 (0)7056 9398-0                             FAX: +49 (0)7056 9398-29
                                           Toll Free in Germany: 0800 639 7678
                                           e-mail: [email protected]

United Kingdom:

 

One Omega Drive, River Bend Technology Centre

 ISO 9002 Certi ed

             

Northbank, Irlam, Manchester

                                           M44 5BD United Kingdom 
                                           TEL: +44 (0)161 777 6611                            FAX: +44 (0)161 777 6622
                                           Toll Free in United Kingdom: 0800-488-48
                                           e-mail: [email protected]

        OMEGAnet

®

 Online Service

Internet e-mail

www.omega.com                             [email protected]

Summary of Contents for FP90 Series

Page 1: ...IES Flow Transmitters Flow6 25GPM Total1234567 8 www omega com e mail info omega com Shop online at ISO9002 CERTIFIED CORPORATEQUALITY MANCHESTER UK ISO9001 CERTIFIED CORPORATE QUALITY STAMFORD CT Use...

Page 2: ...C OMEGA Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN TELEX 996404 EASYLINK 62968934 CABLE OMEGA Mexico En Espa ol 001 203 359 7803 e mail espanol om...

Page 3: ...mA 5 VDC 1 3 or 4 wire 20 mA 5 VDC 1 Optically isolated from current loop Short circuit protected Current output 4 to 20 mA isolated fully adjustable and reversible Max loop impedance 50 max 12 V 325...

Page 4: ...ble length is 200 ft for FP5100 FP5200 FP5300 FP6000 and any sinusoidal ow signal Maximum cable length is 1000 ft for FP 5600 FP8501 FP2540 FP3 1500 FMG 3000 and FMG 550 and any square wave ow signal...

Page 5: ...r AUX Power System Pwr Loop System Pwr Loop AUX Power AUX Power 4 3 2 1 4 3 2 1 Transmitter 2 Terminals 4 3 2 1 PLC Terminals Loop Input 4 20 mA Transmitter Terminals System Pwr Loop System Pwr Loop A...

Page 6: ...r Terminals Power Supply 12 24 VDC Connection to a PLC with built in power supply Internal PLC Connection Connection to a PLC Recorder separate supply Example Two transmitters connected to PLC Recorde...

Page 7: ...on no current loop used Trans mitter Terminals Power S upply 12 24 VDC Connection to a PLC with built in power supply Internal PLC Connection Connection to a PLC Recorder separate supply Example Two t...

Page 8: ...n the ow rate moves above the setpoint plus the hysteresis value High Open Collector or Relay output Output triggers when the ow rate is greater than the setpoint The output will deenergize when the o...

Page 9: ...VIEW displays below are temporary The permanent display will return after ten minutes Flow1 123 4 GPM Flow2 567 8 GPM Delta Flow 10 5 GPM Tot1 1234567 8 Tot2 123456 78 Perm1 1234567 8 Gallons Perm2 12...

Page 10: ...Key Code is UP UP UP DOWN keys in sequence After entering the Key Code the display will show the rst item in the selected menu Step 3 Scroll menu with UP or DOWN arrow keys Step 4 Press RIGHT ARROW k...

Page 11: ...or different by x10 or x100 Limits 0 0001 to 99999 The K factor cannot be set to 0 Select the minimum and maximum values for the 4 20 mA Current loop output The FP90 will allow any values from 0 0000...

Page 12: ...epresents the precise current output Adjustment limits 3 80 mA 4 00 mA 5 00 mA 19 00 mA 20 00 mA 21 00 ma Use this setting to match the system output to any external device Active HIGH This setting is...

Page 13: ...ection upper or lower case This setting tells the transmitter how to convert the input frequency from the ow sensor into a volumetric total It also is used as the basis for the volumetric Pulse mode T...

Page 14: ...d output response Locked The Key Code must be entered to reset the resettable totalizer Unlocked No key code required to reset the resettable totalizer Adjust the minimum and maximum current output Th...

Page 15: ...alues for the Current loop output 1 The FP90 will allow any values from 0 0000 to 99999 Select the input source for Open Collector output 1 Flow sensor 1 Flow sensor 2 or Delta Flow Select the mode of...

Page 16: ...s Longer averaging produces more stable display and output response Lock Off No key code required to reset the resettable totalizer Lock On The Key Code must be entered to reset the resettable totaliz...

Page 17: ...t Volume setting Decrease pulse width setting Reduce system ow rate Enter K factor between 0 0001 to 99999 Reset the hysteresis value Flow rate exceeds display capability Relay or Open Collector pulse...

Page 18: ...page 16 OMEGA FP90 Series Flow Transmitter Instructions Notes...

Page 19: ...t liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS...

Page 20: ...rs Air Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pump...

Reviews: