ECD 15B / 40B / 90B / 150B - Installation and operating manual 

 

 

 

Technical data 

 

 

Please take the relevant climate zone into account when dimensioning yours specific ECD 

series application. 

 

Northern Europe, Canada, Northern USA, Central Asia 

Central and Southern Europe, Central America 

South East Asian coastal regions, Oceania, Amazon and Congo regions 
 

 

 

Type 

ECD 15B 

ECD 40B 

ECD 90B 

ECD 150B 

Voltage 

115 VAC 

115 V +/-10% 

230 VAC 

230 V +/-10% 

Power 

115 VAC 

24 VA 

230 VAC 

24 VA 

Frequency 

50 – 60 Hz 

Operation pressure range 

0 – 16 bar / 0 – 232 psi 

Drain capacity (7 bar / 101 

psi) 

15 l/h 

0,0088 scfm 

40 l/h 

0,0235 scfm 

90 l/h 

0,0529 scfm 

150 l/h 

0,0882 scfm 

Operating temperature 

range 

1,5 – 65°C 

1,5 – 65°C 

1,5 – 65°C 

1,5 – 65°C 

Inlet connection 

G 1/2" 

G 1/2" 

G 1/2" 

G 1/2" 

Outlet connection 

G 1/8" 

G 1/8" 

G 1/8" 

G 1/8" 

Power interface 

3 x 0,75mm

2

 

3 x 0,75mm

2

 

3 x 0,75mm

2

 

3 x 0,75mm

2

 

Protection class 

IP54 

IP54 

IP54 

IP54 

Volume 

0,15 l 

0,15 l 

0,2 l 

0,28 l 

Mass 

0,9 kg 

0,9 kg 

1,05 kg 

1,15 

Dimensions A x B x C [mm] 

120 x 82 x 125 

120 x 82 x 125 

120 x 82 x 135 

120 x 82 x 150 

 

Peak Compressor 

Performance 

[m

3

/min]

 

11,6 

29,4 

60,6 

111,6 

9,3 

23,5 

48,5 

89,3 

5,8 

14,7 

30,3 

55,8 

Peak Dryer 

Performance 

[m

3

/min]

 

23,2 

58,8 

121,2 

223,2 

18,6 

47,0 

97,0 

178,6 

11,6 

29,4 

60,6 

111,6 

Peak Filter 

Performance 

[m

3

/min]

 

116 

294 

606 

1116 

93 

235 

485 

893 

58 

147 

303 

558 

Compressor power [kW] 

Up to 30 

Up to 75 

Up to 160 

Up to 315 

Summary of Contents for ECD 15B

Page 1: ...re installing electronic drain unit into service Trouble free and safe operating of the unit can only be guaranteed if recommendations and conditions stated in this manual are respected Installation a...

Page 2: ...235 scfm 90 l h 0 0529 scfm 150 l h 0 0882 scfm Operating temperature range 1 5 65 C 1 5 65 C 1 5 65 C 1 5 65 C Inlet connection G 1 2 G 1 2 G 1 2 G 1 2 Outlet connection G 1 8 G 1 8 G 1 8 G 1 8 Power...

Page 3: ...ualified electrician Do not exceed max operating pressure or operating temperature range see data label Do not use the device in hazardous areas with potentially explosive atmospheres Use original spa...

Page 4: ...al to electronic board Electromagnetic valve 4 is than opened to discharge accumulated condensate through outlet connection 5 When reservoir 2 has been emptied the valve 4 closes back without any loss...

Page 5: ...mmended Install ball valves 2 only Recommended connection 4 to water oil separator 1 2 The inclination of the unit must not exceed 5 in both axes If device is not installed correctly it could cause fa...

Page 6: ...d air prevents the condensate being purged from drain 5 During installation ensure that no water pockets are formed in the piping 6 7 8 When drainage is to take place directly from a pipeline it is re...

Page 7: ...connections cannot be used as condensate inlet at the same time 13 14 STANDARD INSTALLATION Upper connection Inlet Back connection Closed VENTING LINE INSTALLATION Upper connection Air ventilation Ba...

Page 8: ...Three flashes ECD 90B 4 Four flashes ECD 150B Operating LED indicates a condensate sensor output 1 Green FLASHES Sensor detects no water 2 Green ON Condensate is detected 3 Red ON Alarm mode Short fla...

Page 9: ...ate is doubled This mode lasts for five minutes In case the reservoir empties during overload mode the drain enters normal mode again Otherwise it goes into alarm mode ALARM If drain was still not abl...

Page 10: ...nge sealings Attention Before beginning maintenance work take the drain out of operation cut off the power supply and depressurize the unit Service kits Service Kit type Order number Description Servi...

Page 11: ...pring 12 Plunger 13 Valve housing 14 O ring 5 8x1 5 15 Coil 16 O ring 5 8x1 5 17 Valve connector 18 Screw M3 DIN912 19 Screw M3x30 20 Extension hose 21 Internal strainer 22 Sealing 23 O ring 7x2 24 Bo...

Page 12: ...ce worn parts Check if intense corrosion is present in the system Permanent red LED flashes Device is in one of production modes Contact supplier Warranty exclusion The guarantee shall be void if The...

Reviews: