background image

Section 2 - Installation

2.1 Unpacking

Remove the packing list and verify that you have received all your equipment. 

If you have any questions about the shipment, please call our Customer 

Service Department at 

1-800-622-2378

 or 

203-359-1660

. We can also be reached 

on the Internet at 

omega.com

, e-mail: 

[email protected]

When you receive the shipment, inspect the container and equipment for any 

signs of damage. Note any evidence of rough handling in transit. Immediately 

report any damage to the shipping agent.

NOTE:

The carrier will not honor any damage claims unless all shipping 

material is saved for inspection. After examining and removing 

contents, save packing material and carton in the event  

reshipment is necessary.

The following items are supplied in the box:
• CSi32 Series benchtop Controller (1 each)
• This Users Guide and Controller Manual #M3355, iSeries Temperature & 

Process Controllers (1 each)

• Power Cord (1 each)
• Mating Input Connector(s), Thermocouple Model (1 each) standard OST  

Series male and (1 each) miniature SMP Series male.

• DB9-R12 Cable/Adaptor (1 each) Communication models only.
• Communications Manual #M3397 (1 each) Communications models only.

2.2 Power Connection

2.2.1 108 to 125 Vac, 50/60 Hz Model

Your Benchtop Controller comes with a standard North American 3-prong AC 

power cord. Do not use any other power cord other than the one provided. 

This cord provides the proper grounding and has been safety tested by the 

proper safety agencies.

CAUTION:

Electrical connections and wiring should be performed only by 

suitably trained personnel.

3

Installation

2

Summary of Contents for CSi32

Page 1: ...bine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industri...

Page 2: ...CSi32 Benchtop Controller e mail info omega com For latest product manuals www omegamanual info Shop online at omega com User sGuide RoHS 2 Compliant...

Page 3: ...6 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide omega com info omega com The information contained in this document is believed...

Page 4: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 5: ...Rear Panel Connection Thermocouple Models 4 3 3 Rear Panel Connection RTD MV MA Models 5 3 4 Controller Settings and Programming 6 Section 4 RS232 485 Communication 7 4 1 Cable Connections 7 4 2 Softw...

Page 6: ...mbols 1 2 Available Models 2 3a Front Panel 108 to 125 Vac Models 4 3b Rear Panel Thermocouple Models 4 3c Rear Panel RTD Models 5 3d Rear Panel MV and MA Models 5 4 Internal Wiring Benchtop Controlle...

Page 7: ...CONNECT MAIN POWER CORD BEFORE ATTEMPTING ANY MAINTENANCE OR FUSE REPLACEMENT DO NOT CONNECT AND OR OPERATE THIS UNIT TO AN NON GROUNDED NON POLARIZED OUTLET OR POWER SOURCE DO NOT RECONFIGURE THE INP...

Page 8: ...odels Figure 2 Available Models Introduction 1 2 AVAILABLE INPUT CONTROL TEMPERATURE MODELS TYPE OUTPUT RANGE CSi32J J 210 to 760 C 346 to 1400 F CSi32K K 270 to 1372 C 454 to 2502 F CSi32E E 270 to 1...

Page 9: ...in the event reshipment is necessary The following items are supplied in the box CSi32 Series benchtop Controller 1 each This Users Guide and Controller Manual M3355 iSeries Temperature Process Contr...

Page 10: ...RS 1 EA STANDARD SIZE CONNECTOR AND 1 EA MINIATURE SIZE CONNECTOR INCLUDED AC MAINS RECEPTACLE 108 120 VAC 50 60 Hz POWER CORD PROVIDED OUTPUT 2 5 AMP 120V MAX 600 WATTS CONTROLLER REAR PANEL VIEW FOR...

Page 11: ...IRE RTD 100 1 2 3 4 5 4 WIRE 3 WIRE 2 WIRE OUTPUT 1 FUSE F2 F5A 250V 5mm DIA X 20mm LONG OUTPUT 2 FUSE F3 F5A 250V 5mm DIA X 20mm LONG RS232 485 OPTION PORT RJ12 JACK MODELS C2 OR C4 ONLY 5 POSITION T...

Page 12: ...to show SP1 With SP1 on the display press the ENTER key to show the current programmed setpoint known as SV Setpoint Variable To make changes to the setpoint press the INCREASE or DECREASE key follow...

Page 13: ...nication software for configuration The software is designed to interface with your benchtop controller when the optional communication hardware has been factory installed in your unit Note The iSerie...

Page 14: ...oth with a mild cleaning solution and gently clean the benchtop controller 5 3 Fuse Replacement WARNING Disconnect all power from source before attempting fuse replacement CAUTION For continued protec...

Page 15: ...ll electrical connections b Check rear panel fuses c Check that you have programmed and set all the correct parameters for your application Ref Manual No M3355 3 Rear Panel Output Fuse s a Check all e...

Page 16: ...RTD MA MV Models 5 Position terminal block with 3 48 Phillips head screws Accepts wire from 16 to 30 AWG Output Connection Outputs 2 Output Rating 5 Amp 120 Vac Max Output Connections Standard 3 Prong...