background image

-

+10 Vdc

FIG.10

 350 

+

-

+

-

POWER SUPPLY
The side label, shows
the type and value of
the power supply.

SIGNAL OUTPUT
Current

SIGNAL OUTPUT
Voltage

P O W E R
SUPPLY

OUTPUTS / SALIDAS
        mA          Vdc

INPUT / ENTRADA

S

U

PPL

Y /

 A

L

IM

EN

T

A

C

IO

N

3    4    5    6

9   10   11   12

7

1

+

Lo

H i 

+

-

-

OUTPUTS
SALIDAS

     AC 
VOLTAGE

3    4    5    6

1     2

      POWER SUPPLY
FUENTE ALIMENTACION

TARE ADJUST

When internal tare
adjust (on the "ME"
input board ) is not
used, the signal
conditioner terminals
3 and 4, must not be
connected.

POWER
SUPPLY

SIGNAL OUTPUT
Current

SIGNAL OUTPUT
Voltage

OUTPUTS / SALIDAS
        mA          Vdc

INPUT / ENTRADA

S

U

P

P

L

Y

 /

 AL

IM

E

N

T

ACI

O

N

3    4    5    6

9   10   11   12

7

1

+

Lo

H i 

+

-

-

OUTPUTS
SALIDAS

     AC 
VOLTAGE

3    4    5    6

1     2

      POWER SUPPLY
FUENTE ALIMENTACION

POWER SUPPLY
The side label,
shows the type
and value of the
power supply.

4-WIRE
BRIDGE

+10 Vdc

 350 

+

-

+

-

6-WIRE
BRIDGE

WIRING

CONNECTIONS

FIG.9

4

9

POWER SUPPLY

RECOMMENDED WIRING

The power supply must be connected to terminals 1 and 7. The characteristics of the power supply
are shown on the side label.

WARNING.- 

If the power supply is dc voltage, be careful with the polarity indicated for each

terminal.

FIG. 3

O UTPUTS / SALIDAS
        m A          Vdc

INPUT / ENTRADA

SU

P

P

L

Y

 /

 A

L

IM

EN

T

A

C

IO

N

3     4     5      6

9   10   11   12

7

1

+

Lo

H i 

+

-

-

PRECAUTIONS

The installation must incorporate safety devices
to protect the operator and the process when
using the Transmitter to control a machine or
process where injury to personnel or damage to
equipment or process, may occur as a result of
failure of the Transmitter.

     Power

Fuse

     supply

value

230 Vac

  50 mA

115 Vac

100 mA

48 Vac

150 mA

24 Vac

300 mA

24 Vdc

300 mA

PROTECTIONS

See on table 1 the recommended value of the
fuse for the different power supply availables.

CHANGING THE POWER SUPPLY

The unit is not provided with a system to change the power supply. Therefore if the power supply
must be modified to other value, please replace the module MA for another one appropriate to
the new characteristics. Contact your local distributor for instructions.

TABLE 1

Fuse

Power supply

Summary of Contents for CCT-80 Series

Page 1: ...M2218 1201 http www omega com e mail info omega com User sGuide CCT 80 Strain Gage Signal Conditioners...

Page 2: ...France 0800 4 06342 e mail france omega com Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Tel 49 07056 3017 FAX 49 07056 8540 Toll Free in Germany 0130 11 21 66 e mail germany omega...

Page 3: ...Changing the Power Supply 4 Signal Output module MS 5 Changing the Signal Output 5 Signal Input module ME Overview 6 CCT 80 Electrical Features Specifications 7 Signal Input Range Selection 8 Adjustm...

Page 4: ...the case the following must be checked The front label blue color must be in its correct position with terminals 1 and 7 power supply separated from the other terminals The three internal modules must...

Page 5: ...e Transmitter to control a machine or process where injury to personnel or damage to equipment or process may occur as a result of failure of the Transmitter Power Fuse supply value 230 Vac 50 mA 115...

Page 6: ...4 to 20 mA unless specified otherwise To select a 0 to 10 V output remove jumpers E and F as shown in Figure 6 Other non standard output voltage and current ranges may be obtained by adding and or re...

Page 7: ...if closed Adjust the low range level of the output Offset negative fine AMPLIFIER GAIN Jumper B if closed Gain at maximum level Jumper C if closed Gain at medium level Jumpers B and C opened Gain at...

Page 8: ...SUMPTION 1 5 VA TEST VOLTAGE 4 kVeff 50 Hz 1m This signal conditioner provides connection to 4 or 6 wire strain gages load cells which provide a nominal of 2 mV V or 3 mV V output with 350 impedance S...

Page 9: ...als to be used 5 Power up the signal conditioner with the correct power supply 6 Adjust the calibrator until it generates the low signal level 0 Vdc 7 Turn the ZERO trimmer P1 located on the ME input...

Page 10: ...ENTACION TARE ADJUST When internal tare adjust on the ME input board is not used the signal conditioner terminals 3 and 4 must not be connected POWER SUPPLY SIGNALOUTPUT Current SIGNALOUTPUT Voltage O...

Page 11: ...Lo H i TECHNICAL DATA WEIGHT 270 g HOUSING BASE Polycarbonate RAL 7032 UL 94 V 1 light grey IP 40 TERMINAL HOUSING COVER AND BLIND PLUGS Polycarbonate UL 94 V 2 dark grey IP 20 WIRE CROSS SECTION 4 mm...

Page 12: ...NOTES 11...

Page 13: ...rwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by...

Page 14: ...ystems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity...

Reviews: