Safety instructions 

2.1.

 

Product safety 

Product should only be used in a technically perfect condition and in the intended, safety 
and danger-aware method, taking into account the operating instructions. 

2.1.1.

 

Safety instructions regarding transport and storage 

 

The product must be transported and stored in its protective packaging until it is 
installed. 

 

The product must be stored in dirt-free, moist-free and frost-free space. 

2.1.2.

 

Safety instructions regarding operation 

 

The pipeline system must be properly designed and installed so that the drain can be 
mounted and operated without tension. 

 

Drain must be properly installed in the correct mounting position. 

 

Operate with the product only with protective equipment. 

 

In the event of malfunction, stop and secure the product immediately. Any fault must 
be rectified immediately. 

 

Do not exceed max. operating pressure or operating temperature range (see 
Technical data). 

2.1.3.

 

Safety instructions regarding installation, maintenance and service 

 

Installation and maintenance work may only be carried out by trained and 
experienced staff. 

 

Depressurize the system before carrying out any work on the piping. 

 

Installation and maintenance work may only be carried out when the product is not 
under pressure. 

 

Do not exceed max. operating pressure or operating temperature range (see data 
label). 

 

Use original spare parts only. 

 

Use the product for the appropriate purpose only. 

 

Can be used in hazardous areas (a product does not have its own potential ignition 
source) 

 

In case of toxic or hazardous media, the system must be completely drained before 
the product is removed. 

 

In case the product is used with toxic or hazardous media, it must be properly 
decontaminated for maintenance. 

 

Personnel must be equipped with appropriate electrostatic conductive (dissipative) 
clothing including footwear and non-sparking tools.

 

 

Only qualified personnel who pose knowledge and experience with pressurized gas 
systems and ATEX applications can operate the device or perform any kind of work 
related to the device.

 

 

Product must be grounded via dedicated connection.

 

Summary of Contents for AOK 20SS Ex

Page 1: ...Installation and operating manual Document 3403490 Rev 001 Date 25 9 2020 AOK 20SS Ex...

Page 2: ...ty instructions regarding operation 4 2 1 3 Safety instructions regarding installation maintenance and service 4 3 Appropriate use 5 3 1 Intended usage 5 4 Product description 6 4 1 Components 6 4 2 O...

Page 3: ...important information for operating the product safely and properly Following the instructions in this manual will help to avoid dangers minimise repair costs and downtimes and increase the reliabilit...

Page 4: ...ons regarding installation maintenance and service Installation and maintenance work may only be carried out by trained and experienced staff Depressurize the system before carrying out any work on th...

Page 5: ...ain should be installed at a low point of the pipe section This is an automatic function and does not need any additional electrical energy Depending on the liquid level a float controls the drainage...

Page 6: ...x8 4 1x External tooth washer 5 1x Housing lid 6 1x O ring sealing 71 x 2 7 1x Float holder 8 2x Rivet 9 1x Nozzle 10 2x Wire 11 1x Flat seal 12 1x Housing 13 1x Test lever button 14 1x O ring sealing...

Page 7: ...ut connection When condensate level drops floater drops with it and blocks the discharge orifice This operation prevents air loss On the front side of the drain is a TEST button which if rotated in a...

Page 8: ...uest Outlet connection G NPT on request Reservoir volume 0 4 l Weight 5 835 kg Dimensions A x B x C 157 mm x 100 mm x 100 mm Valve type Direct acting normally closed Capacity calculation For rough cal...

Page 9: ...impurities within it Install the drain at a level below the receiver if not the receiver will fill up with condensate Earthing of the product must be done with wire of cross section 1 5 mm2 Make eart...

Page 10: ...ularly Intervals of cleaning depend on contamination of condensate Replace the sealings if necessary Make a visual check of the drain and make sure there is no visual damage or leakage 7 1 Service It...

Page 11: ...l commissioning and maintenance The unit was not operated properly and appropriately The unit was operated when it was clearly defective Non original spare parts or replacement parts were used The uni...