background image

10 

 

7.

 

Maintenance 

The automatic operation of the product requires maintenance to ensure that it continuous 
to operate perfectly. 

 

 Before maintenance depressurize the product and keep 
to the safety rules when working with pressure 
equipment. 

Weekly: 

 

Rotate the "Test" button and manually drain the accumulated condensate until air begins 
to blow from the drain. If a significant amount of water (more than 0.5 litres) exits the 
valve then the drain must be thoroughly cleaned. 

Monthly: 

 

Visually check seals on the body and the pipe connection, make sure there is no leakage.

 

 

If strainer is installed prior the drain, check and clean it. 

Yearly:  

 

Clean interior of the reservoir regularly. Intervals of cleaning depend on contamination 
of condensate.  

 

Replace the sealings if necessary.  

 

Make a visual check of the drain and make sure there is no visual damage or leakage. 

7.1.

 

Service 

It is recommended to clean the reservoir at least once a year. Sealing elements are subject 
to wear, which depends on various operating parameters such as pressure, temperature, 
dirt content, etc. It is also recommended to change seals.  

7.2.

 

Spare parts 

Replacement seals are available on demand. Please contact your distributor or 
manufacturer. 

8.

 

Transport and storage 

A product must be handled, transported and stored with care: 

 

The product must be transported and stored in its protective packaging until it is 
installed. 

 

When the product is stored prior to installation, it should be kept in closed rooms 
and protected against harmful influences such as dirt, moist and frost. 

Summary of Contents for AOK 20SS Ex

Page 1: ...Installation and operating manual Document 3403490 Rev 001 Date 25 9 2020 AOK 20SS Ex...

Page 2: ...ty instructions regarding operation 4 2 1 3 Safety instructions regarding installation maintenance and service 4 3 Appropriate use 5 3 1 Intended usage 5 4 Product description 6 4 1 Components 6 4 2 O...

Page 3: ...important information for operating the product safely and properly Following the instructions in this manual will help to avoid dangers minimise repair costs and downtimes and increase the reliabilit...

Page 4: ...ons regarding installation maintenance and service Installation and maintenance work may only be carried out by trained and experienced staff Depressurize the system before carrying out any work on th...

Page 5: ...ain should be installed at a low point of the pipe section This is an automatic function and does not need any additional electrical energy Depending on the liquid level a float controls the drainage...

Page 6: ...x8 4 1x External tooth washer 5 1x Housing lid 6 1x O ring sealing 71 x 2 7 1x Float holder 8 2x Rivet 9 1x Nozzle 10 2x Wire 11 1x Flat seal 12 1x Housing 13 1x Test lever button 14 1x O ring sealing...

Page 7: ...ut connection When condensate level drops floater drops with it and blocks the discharge orifice This operation prevents air loss On the front side of the drain is a TEST button which if rotated in a...

Page 8: ...uest Outlet connection G NPT on request Reservoir volume 0 4 l Weight 5 835 kg Dimensions A x B x C 157 mm x 100 mm x 100 mm Valve type Direct acting normally closed Capacity calculation For rough cal...

Page 9: ...impurities within it Install the drain at a level below the receiver if not the receiver will fill up with condensate Earthing of the product must be done with wire of cross section 1 5 mm2 Make eart...

Page 10: ...ularly Intervals of cleaning depend on contamination of condensate Replace the sealings if necessary Make a visual check of the drain and make sure there is no visual damage or leakage 7 1 Service It...

Page 11: ...l commissioning and maintenance The unit was not operated properly and appropriately The unit was operated when it was clearly defective Non original spare parts or replacement parts were used The uni...

Page 12: ...12 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega air si...