background image

1.0 Information on height of hands

V8AH4 

#

H1B

Manufacturing code

Hand height (H1) and version (B)

V8AH4 

#

H1

B

OMEGA SA  

WORLD SERVICE ORGANIZATION  

GT-19-C-052-E - A - 5200

Specific information for Calibre 5200

/

Fig. 1.0

Designation

Movement holder 

for hand setting

No of runners for 

hand setting

Minimum force 

(N)

Maximum force 

(N)

Support 

(jewel)

Hours hand

507 0041

5

10

30

no

Minutes hand

2

10

30

no

Seconds hand

1

10

20

yes

Hour counter hand

1

10

20

yes

Minute counter hand

1

10

20

yes

Chrono second hand

1

15

30

yes

1.1 Runners for hand setting and hand 

 

setting force

Summary of Contents for 5200

Page 1: ...and gilded engraving Three hand display hours minutes and seconds Chronograph with minute and 30 minute counters and 1 10 second and 60 second counters Rate adjustment by inhibition Stepper motor with...

Page 2: ...Page Contents OMEGA SA WORLD SERVICE ORGANIZATION GT 19 C 052 E A 5200 Differences between 5200A and 5200B 4 Spare parts list for Calibre 5200 5 Electrical tests 7...

Page 3: ...t recommended to remove the gear train from the motor module without the specially adapted holder ref 506 0005 Movement exchange is recommended According to Working Instruction 31 Repair and movement...

Page 4: ...5200B V 8 A H 4 H 1 B V 8 A H 4 H1 B RoHS version Calibre 5200B V 8 A F 1 H 1 V 8 A F 1 H1 Non RoHS version Calibre 5200A Differences between a non RoHS version and a RoHS version OMEGA SA WORLD SERV...

Page 5: ...ON GT 19 C 052 E A 5200 Battery Version Reference 5200A 1449917 5200B Hand setting stem 0 90 mm Version Reference 5200A 722520051020 5200B Battery limitation spring Version Reference 5200A 72252001060...

Page 6: ...formation for Calibre 5200 Fig 1 0 Designation Movement holder for hand setting No of runners for hand setting Minimum force N Maximum force N Support jewel Hours hand 507 0041 5 10 30 no Minutes hand...

Page 7: ...tart Measured without battery variable external supply dropping by 1 55 V when motor s stopped 3 10 k ROUGE 1 5 2 1 k VERT 1 2 1 8 k Coil continuity Coils are checked when the basic movement of the mo...

Page 8: ...d hand 30 minute counter 1 10 second counter 3 0 Display Watch hands 3 1 Counter initialisation Crown in position II or III Initialisation of the 60 second counter hand Initialisation of the 1 10 seco...

Page 9: ...le 5 minutes 57 seconds 7 10 second RESET Caution The chronograph hands must be in their original position before starting a new timing operation See Counter initialisation 3 1 3 1 2 3 5 Timing mode a...

Page 10: ...the reading 3 2 STOP 2 Reading the intermediate time Example time 2 15 minutes 36 seconds 8 10 seconds RESTART split second The chronograph hands make up the time elapsed during the reading 5 4 STOP...