background image

General information for Calibre 5200 

Major points

 

Information on the battery (ref. 1449917)

1,55 V 

«Low Drain»

Ø 9,50 mm 

H 3,60 mm

Renata 

394

Vartachron 

V394

UCAR, Energizer, Ray-O-Vac 394
Maxell, Sony, Panasonic

SR616SW

Battery limitation spring position

Points to comply with

The battery limitation spring MUST be used to keep the 

battery firmly in place.

Move the setting stem switch to position 3 to extract or 

insert the setting stem.

It is not recommended to remove the gear-train from the 

motor module without the specially-adapted holder, 

ref. 506 0005

Movement exchange is recommended

According to Working Instruction 31. Repair and 

movement exchange policy.

Information on setting of hands

 

The hands must be fitted by means of force-compensated 

broaches.  All hands must be fitted with the appropriate 

movement-holder ref. 507 0041 with jewel support.

Mandatory tools :

Hand fitting 

 

Ref.

Movement-holder for fitting 

507 0041 

center & counter hands

Movement holder for hand setting 

507 0041 

Tweezers

Plastic tweezers 

 

502 310 0051

OMEGA SA  

WORLD SERVICE ORGANIZATION  

GT-19-C-052-E - A - 5200

/

Summary of Contents for 5200

Page 1: ...and gilded engraving Three hand display hours minutes and seconds Chronograph with minute and 30 minute counters and 1 10 second and 60 second counters Rate adjustment by inhibition Stepper motor with...

Page 2: ...Page Contents OMEGA SA WORLD SERVICE ORGANIZATION GT 19 C 052 E A 5200 Differences between 5200A and 5200B 4 Spare parts list for Calibre 5200 5 Electrical tests 7...

Page 3: ...t recommended to remove the gear train from the motor module without the specially adapted holder ref 506 0005 Movement exchange is recommended According to Working Instruction 31 Repair and movement...

Page 4: ...5200B V 8 A H 4 H 1 B V 8 A H 4 H1 B RoHS version Calibre 5200B V 8 A F 1 H 1 V 8 A F 1 H1 Non RoHS version Calibre 5200A Differences between a non RoHS version and a RoHS version OMEGA SA WORLD SERV...

Page 5: ...ON GT 19 C 052 E A 5200 Battery Version Reference 5200A 1449917 5200B Hand setting stem 0 90 mm Version Reference 5200A 722520051020 5200B Battery limitation spring Version Reference 5200A 72252001060...

Page 6: ...formation for Calibre 5200 Fig 1 0 Designation Movement holder for hand setting No of runners for hand setting Minimum force N Maximum force N Support jewel Hours hand 507 0041 5 10 30 no Minutes hand...

Page 7: ...tart Measured without battery variable external supply dropping by 1 55 V when motor s stopped 3 10 k ROUGE 1 5 2 1 k VERT 1 2 1 8 k Coil continuity Coils are checked when the basic movement of the mo...

Page 8: ...d hand 30 minute counter 1 10 second counter 3 0 Display Watch hands 3 1 Counter initialisation Crown in position II or III Initialisation of the 60 second counter hand Initialisation of the 1 10 seco...

Page 9: ...le 5 minutes 57 seconds 7 10 second RESET Caution The chronograph hands must be in their original position before starting a new timing operation See Counter initialisation 3 1 3 1 2 3 5 Timing mode a...

Page 10: ...the reading 3 2 STOP 2 Reading the intermediate time Example time 2 15 minutes 36 seconds 8 10 seconds RESTART split second The chronograph hands make up the time elapsed during the reading 5 4 STOP...