U.S. Patent No. 8,856,780
XX-XX
PAGE X-X
XX-XX
PAGE X-X
MODULE PROGRAMMING PROCEDURE - WITH TWO OEM KEYS
12
Module Programming
Procedure completed.
1
Insert key 1 into ignition.
5
Insert key 2 into ignition.
3
If LED turns solid GREEN for 2
seconds. Module Programming
Procedure completed.
If LED turns solid RED, proceed
with following step within 5
seconds, after LED turns OFF.
9
Press and release programming
button.
10
Remote start vehicle.
OR
Jump the igntion to 12volts.
12V
IGNITION
10 AMPS
2
Turn key 1 to ON position.
ON
6
Turn key 2 to ON position.
ON
!
If the LED begins to fl ash RED, verify the RX and TX
connections between the module and the vehicle.
!
If the LED begins to fl ash RED, you are using a cloned
key or used the same key twice.
7
Wait, LED will turn solid RED
then will turn OFF.
11
Wait, LED will turn solid RED
then will turn solid GREEN.
NOTE
I
To complete this procedure,
both OEM keys are required.
II
Keep both OEM remotes
at least 10 feet away from
the vehicule.
Use both valet keys for the
module programming procedure.
Æ
Æ
OR
4
Remove key.
8
Remove key.
ADS-AL(TB)-FM2
PAGE 1-4
Page 13 of 15
ol-al(mib)-Fm2-en
20141105
inStall GUide
automotive data Solutions inc. © 2014
ImmobIlIzer bypass
Ford/Mazda
Doc. No.: ##17294##