10
LOAD - PRESSURE CORRELATION CHART
Models 50040 & 50100
Always monitor the force applied to work piece by using a load cell and indicator or you may monitor pressure
developed in the ram by using an in-line pressure gauge, then calculate the applied force using the formula:
F = P x A
where
F
= Force/ Load (lbs)
P
= Hydraulic Working Pressure (psi) and
A
= Ram Effective Area (in²)*
Load
(lbs)
Pressure (psi) of 4 Ton
Ram, where A = 0.998 in
2
Pressure (psi) of 10 Ton
Ram, where A = 2.411 in
2
1,000
1,002
415
2,000
2,004
830
3,000
3,006
1,244
4,000
4,008
1,659
5,000
5,010
2,074
6,000
6,012
2,489
7,000
7,014
2,903
8,000
8,016
3,318
9,000
3,733
10,000
4,148
11,000
4,562
12,000
4,977
13,000
5,392
14,000
5,807
15,000
6,221
16,000
6,636
17,000
7,051
18,000
7,466
19,000
7,881
20,000
8,295
*For Model 50040,
A
= 0.998 in²; For Model 50100,
A
= 2.411 in²
Example 1
Model 50040 exerting 5,000 lbs of force will require what pressure?
Pressure = Force
Ram Effective Area
=
5,000 lbs
0.998 in² = 5,010 psi
Example 2
Model 50100 operating at 6,000 psi will generate what force?
Force = Pressure
x
Ram Effective Area =
6,000 psi x 2.411 in
2
= 14,466 lbs