background image

1

SECTION 1 - INTRODUCTION

The model OS136 series is a very low-cost, super-compact infrared transmitter. It
measures temperature via non-contact, and provides an analog output
proportional to the measured temperature. The OS136 series is offered in two
temperature ranges: -18 to 204ºC (0 to 400ºF) and 149 to 538ºC (300 to 1000ºF).
The analog output is offered as 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, 10
mV/Degree C or F, or K type thermocouple.

The unit has a fixed Emissivity of 0.95 which makes it easy to measure
temperature, requiring no adjustments during installation and use.

The super-compact design, 19 mm OD x 89 mm Length (0.75" OD x 3.5" L) is
ideal to measure temperature in confined, and hard to reach places. The Stainless
Steel housing is NEMA-4 rated. The unit comes with a 1.82 m (6') shielded cable
as standard.

SECTION 2 – INSTALLATION

2.1 – Unpacking

Remove the packing list and verify that you have received all your equipment. If
you have any questions about the shipment, please call the Customer Service at:

1-800-622-2378 or 203-359-2208

. We can also be reached on the internet at

omega.com
email: [email protected]

When you receive the shipment, inspect the container and the equipment for any
signs of damage. Note any evidence of rough handling in transit. Immediately
report any damage to the shipping agent.

The carrier will not honor any damage claims unless all the
shipping materials are saved for inspection. After
examination and removing contents, save packing material
and carton in the event reshipment is necessary.

The following items are supplied in the box:

• The infrared transmitter, OS136 with the 1.82 m (6') shielded cable.

• Two Mounting Nuts

• User’s Guide

Introduction

1

NOTE:

Summary of Contents for OS136 SERIES

Page 1: ...ost Non Contact Infrared Temperature Sensor Transmitter CAUTION This product is not intended for medical use or use on humans e mail info omega com For latest product manuals omegamanual info Shop onl...

Page 2: ...Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free...

Page 3: ...mbols iii Section 1 Introduction 1 Section 2 Installation 1 2 1 Unpacking 1 2 2 Electrical Connection 2 Section 3 Operation 3 3 1 Measuring Temperature 3 3 2 Ambient Temperature 3 3 3 Atmospheric Qual...

Page 4: ...Description Page 2 1 General Wiring Diagram 2 3 1 Optical Field of View 3 3 2 Mounting Bracket OS100 MB 4 3 3 Air Purge Collar OS100 AP 4 3 4 Stainless Steel Housing 5 3 5 Water Air Cool Jacket OS136...

Page 5: ...The cable is a multi conductor 24 AWG stranded wire with the rating of 600 VDC 205 C 401 F Teflon insulation Power must be disconnected before making any electrical connections The recommended power...

Page 6: ...4 rated The unit comes with a 1 82 m 6 shielded cable as standard SECTION 2 INSTALLATION 2 1 Unpacking Remove the packing list and verify that you have received all your equipment If you have any que...

Page 7: ...r and output connections Fig 2 1 shows the wiring diagram for different analog outputs Figure 2 1 General Wiring Diagram Accessories Model No Description OS100 MB Mounting Bracket OS136 WC Water Air C...

Page 8: ...tter can operate in an ambient temperature of 0 to 70 C 32 to 158 F without any water cool jacket It can operate from 0 to 200 C 32 to 392 F with the water cool jacket accessory OS136 WC Fig 3 5 3 6 I...

Page 9: ...e following figures show the Mounting Bracket OS136 MB Air Purge Collar OS136 AP Stainless Steel Housing Water Air Cool Jacket OS136 WC and the Water Air Cool Jacket Assembly Figure 3 2 Mounting Brack...

Page 10: ...HEX KNURL 4 76 3 16 WIDE DIMENSIONS mm in 3 4 16 UNF 88 9 3 5 1 83m 6ft 33 27 1 31 19 05 0 75 1 8 NPT COMPRESSION FITTING 2 PLCS 34 80 1 37 85 09 3 35 7 62 0 30 3 4 16 UNF 2B 3 4 16 UNF INLET OUTLET D...

Page 11: ...de 4 2 Operating the Laser Sight Accessory The Laser sight accessory screws onto the front of the transmitter sensor head This accessory is only used for alignment of the transmitter head to the targe...

Page 12: ...5 POWER CABLE ON OFF SWITCH BATTERY PACK POWER SUPPLY OS136 Dimensions mm in OUTPUT 1 mW WAVELENGTH 630 670 nm CLASS II 2 LASER PRODUCT COMPLIES WITH FDA 21CFR 1040 10 EN60825 1 11 2001 LASER RADIATIO...

Page 13: ...uirements Min Load 0 to 5 Vdc 1 K Ohms Min Load 0 to 10 Vdc 2 K Ohms Max Load 4 to 20 mA Power Supply 4 20 mA Min Load 10 mV Deg 10 K Ohms Min Load K T C 100 K Ohms Operating Ambient Temperature No Wa...

Page 14: ...er Beam Diameter Less than 5 mm Beam Divergence Less than 2 mrad Operating Temperature 0 to 50 C 32 to 122 F Operating Relative Humidity Less than 95 RH non condensing Power Switch ON OFF Slide switch...

Page 15: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 16: ...ity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...