background image

omega altise 

 

Introduction 

Thank you for choosing an omega altise portable air conditioner. This manual contains information, 
regulations and warnings which are of fundamental importance if the appliance is to be installed correctly 
and the highest performance, in the safest possible conditions, is to be obtained. We suggest that you read 
the manual carefully before installing or starting up the unit. 

This portable air-conditioning unit is of the mono tube type, is conveniently transportable (on wheels) with an 
air operating system for domestic use. This unit has the following settings for ease of use: 

• 

Ventilate; 

• 

Cool; 

• 

Dehumidify; and 

• 

Heating (APC15RC only). 

The ventilation mode “moves” the air allowing for the recycling of air much like a general fan. 

The cooling mode uses a refrigerated circuit (compressor) to cool the room by transferring the heat from the 
inside to the outside through the air exhaust hose and cooling the air that it returns to the room. 

The dehumidify mode can be used to remove excess moisture in the air. This mode can be used by itself, 
but also works to dehumidify the room while in cooling mode. 

The heating mode makes the unit a “true reverse cycle” unit using a compressor to warm the room by 
transferring the cool air from inside to outside through the air exhaust hose and warming the air that it returns 
to the room. 

 

 

Features of your new Portable Air-Conditioner 

• 

No costly installation required. 

• 

Easily moved with castors and handle.  

• 

Control panel with LCD display. 

• 

Remote control. 

• 

Low noise and strong breeze.  

• 

Auto swing for better air movement. 

• 

On/off timer function. 

• 

Three-minute restart delay to protect compressor.  

 

 

Energy Saving Tips 

1.  Do not cover or restrict the airflow from the Outlet or Inlet grilles.  

2.  The minimum distance from furniture and walls should be 50cm.  

3.  Keep blinds and /or draperies, on any windows, closed during the sunniest part of the day.  

4.  Keep the filters clean. Under normal conditions, the 

filters should be cleaned approximately every 2 

weeks 

(please see the maintenance section for further instructions). Since the filters remove airborne 

particles, more frequent cleaning maybe necessary, depending on the indoor air quality and if you have 
pets inside the home. 

5.  Set the fan speed switch to high cool and the thermostat to the coolest position for the initial start-up, 

then set the Fan switch to Low cool and lower the thermostat to a comfortable setting.  

6.  Ensure all windows and doors to the room you are operating the unit in are closed. 

 

Summary of Contents for APC15

Page 1: ...PORTABLE AIR CONDITIONER APC15 APC15RC...

Page 2: ...lay with the appliance 7 Do not use the appliance for any other purpose than its intended use 8 The appliance must not be used if the guards are not fastened according to instructions 9 When the power...

Page 3: ...unit a true reverse cycle unit using a compressor to warm the room by transferring the cool air from inside to outside through the air exhaust hose and warming the air that it returns to the room Feat...

Page 4: ...Electronic Remote Aqua Chill Pump over Pump over Water injection tray Yes Yes Water full alarm Yes Yes Water drainage Yes Yes Directional louvres Yes Yes Louvre auto swing Yes Yes Plastic window kit Y...

Page 5: ...4 Handle 5 Air inlet grille 6 Castors 4 7 Flexible exhaust hose 8 Water injection port 9 Power cord storage hooks 10 Air filter 11 Air outlet grille 12 Drain outlet for water storage tank 13 Water sto...

Page 6: ...wever it may be necessary for you to modify some aspects of the installation procedures for certain types of windows Once the window kit is in place simply snap the window exhaust adapter into the hol...

Page 7: ...correct mounting of the flexible exhaust hose Figure 8 shows the incorrect mounting of the flexible exhaust hose Fig 7 Fig 6 Fig 8 NOTE The length of the flexible exhaust hose can be extended up to ap...

Page 8: ...unit into energy saving mode only in heat or cool modes The temperature is permanently set at 27O C in cool mode 23 O C in heat mode and the fan speed is set on low These cannot be changed in ECON mo...

Page 9: ...d Heat mode Operating Instructions Fan Mode The Fan or ventilation mode moves the air allowing for the recycling of air much like a general fan Press MODE button or to choose Fan mode Press SPEED butt...

Page 10: ...eating mode makes the unit a true reverse cycle unit using a compressor to warm the room by transferring the cool air from inside to outside through the air exhaust hose and warming the air that it re...

Page 11: ...evaporation rate and the internal water tank may become full and cause the float and micro switch inside the water tank to trigger the WATER FULL indicator In this instance the compressor will shut of...

Page 12: ...g the internal tank If water is left in the unit then it may spill out onto the floor or carpet Maintenance Cleaning Turn off the unit and pull the plug out of the socket before cleaning 1 Clean the s...

Page 13: ...it on an even solid surface less vibrations The unit is noisy The unit is on a tiled surface Mount the unit on a rubber or carpeted base The compressor does not work The overheat protection may be act...

Reviews: