Timer – Off 

• 

When the unit is operating press the 

TIMER

 button to set timer-off. 

• 

The LED will flash 

“ - - ” 

5 times. During this period press 

UP

 or 

DOWN

 buttons to adjust the time from 

0.5h to 24h. 

• 

Time will vary 0.5h each press in the first 3 hours and 1 hour each time thereafter. 

• 

The set time will flash 5 times after adjusting. 

• 

When the set time is reached the unit will turn off automatically. 

 

NOTE:

 When the timer is on you can check the remaining time by pressing the 

TIMER

 button. It will flash 

five times. Press the 

UP

 or 

DOWN

 buttons to adjust the set time. The set time can also be cancelled by 

pressing the 

TIMER

 button again while it is flashing. 

Timer-on and Timer-off modes can not be set to function at the same time. 

 

 

Aqua Chill Technology 

When operating in Cool Mode this unit uses a self-evaporative system that extracts water from humid 
environments and collects it in an internal water tank. 

Once sufficient water is collected it is recycled over the condenser, assisting to cool the condenser and 
internal refrigerant gas faster than only air. Cooler condenser and refrigerant, means improved cooling 
efficiency and performance of the unit.  

Some of the water recycled over the compressor is evaporated and expelled from the machine as water 
vapour through the flexible exhaust hose. 

During very humid conditions the collection of water may be in excess of the evaporation rate and the 
internal water tank may become full and cause the float and micro switch inside the water tank to trigger the 

WATER FULL

 indicator. In this instance the compressor will shut off automatically, and the fan motor will 

stay circulating the air. A buzzer will sound every 5 minutes until the water tank is drained (refer to the 
drainage section). 

Adding Water 

To utilise the full potential of the cool mode of your portable air-
conditioner, we recommend approx 1800mls of water be added 
to the water injection port (located to the right of the handle) 
just prior to initial start up. 

Normally an adequate quantity of water is collected to keep the 
recycling process operating. However, if there is insufficient 
condensing water for the Aqua Chill function to start, the 

Water 

Injection

 indicator on the control panel will illuminate. When 

this occurs, pour approx 1800mls of water into the water 
injection port (see Figure 9.) and the water injection indicator 
will turn off. 

Fig. 9 

In high temperatures (over 30

0

C) or dry climates, adding water to commence the Aqua Chill mode will greatly 

assist the efficiency and operating temperature of the unit, but is not critical to the functioning of the unit. 

Please ensure that you do not over-fill the unit or the water tank full indicator may be triggered. 

Do not fill the water injection port while in dry, fan or heat modes. 

Please Note: Adding water is not a requirement for this unit to function normally. If you choose not to 
add water to this unit it will not adversely affect the warranty or its regular performance. 

 

 

11 

Summary of Contents for APC15

Page 1: ...PORTABLE AIR CONDITIONER APC15 APC15RC...

Page 2: ...lay with the appliance 7 Do not use the appliance for any other purpose than its intended use 8 The appliance must not be used if the guards are not fastened according to instructions 9 When the power...

Page 3: ...unit a true reverse cycle unit using a compressor to warm the room by transferring the cool air from inside to outside through the air exhaust hose and warming the air that it returns to the room Feat...

Page 4: ...Electronic Remote Aqua Chill Pump over Pump over Water injection tray Yes Yes Water full alarm Yes Yes Water drainage Yes Yes Directional louvres Yes Yes Louvre auto swing Yes Yes Plastic window kit Y...

Page 5: ...4 Handle 5 Air inlet grille 6 Castors 4 7 Flexible exhaust hose 8 Water injection port 9 Power cord storage hooks 10 Air filter 11 Air outlet grille 12 Drain outlet for water storage tank 13 Water sto...

Page 6: ...wever it may be necessary for you to modify some aspects of the installation procedures for certain types of windows Once the window kit is in place simply snap the window exhaust adapter into the hol...

Page 7: ...correct mounting of the flexible exhaust hose Figure 8 shows the incorrect mounting of the flexible exhaust hose Fig 7 Fig 6 Fig 8 NOTE The length of the flexible exhaust hose can be extended up to ap...

Page 8: ...unit into energy saving mode only in heat or cool modes The temperature is permanently set at 27O C in cool mode 23 O C in heat mode and the fan speed is set on low These cannot be changed in ECON mo...

Page 9: ...d Heat mode Operating Instructions Fan Mode The Fan or ventilation mode moves the air allowing for the recycling of air much like a general fan Press MODE button or to choose Fan mode Press SPEED butt...

Page 10: ...eating mode makes the unit a true reverse cycle unit using a compressor to warm the room by transferring the cool air from inside to outside through the air exhaust hose and warming the air that it re...

Page 11: ...evaporation rate and the internal water tank may become full and cause the float and micro switch inside the water tank to trigger the WATER FULL indicator In this instance the compressor will shut of...

Page 12: ...g the internal tank If water is left in the unit then it may spill out onto the floor or carpet Maintenance Cleaning Turn off the unit and pull the plug out of the socket before cleaning 1 Clean the s...

Page 13: ...it on an even solid surface less vibrations The unit is noisy The unit is on a tiled surface Mount the unit on a rubber or carpeted base The compressor does not work The overheat protection may be act...

Reviews: