OMEGA AIR WOS Installation And Operating Manual Download Page 7

WOS - Installation and operating manual 

 7 

Maintenance 

 

It is rec ommended, that you do a check once per week to evaluate filter element saturation. 

To test water quality use test set. Instructions are attached in test set. Filter element must 

be replaced when first of the following parameters appears: 

·

 

4000 operating hours of compressor

[3]

 

·

 

12 months regardless compressor operating hours 

·

 

Oil concentration in outlet reaches concentration determined with local directives 

and laws. 

[3]

 At compressor oil carry over 2,5mg/m

3

. Lower/higher oil carry over means proportionally longer/shorter lifetime 

(e.g. if 

oil carryover is 5mg/m

3

 lifetime reduces to 2000 operating hours)

Water quality can also be checked with “oil indicating test paper”. For test set please contact us or your local distributor. 

 

·

 

Damaged components are to be replaced by new ones. If a marked degree of 

damage is found, the entire vessel is to be replaced.  

·

 

Carry out a check for leaks once the maintenance work has been finished. 

 

Warning 

Disposal of used filter elements must be carried out in accordance with local regulations 

and laws. 

 

Warranty exclusion 

 

The guarantee shall be void if: 

·

 

The operating instructions were not followed with respect to initial commissioning 

and maintenance. 

·

 

The unit was not operated properly and appropriately. 

·

 

The unit was operated when it was clearly defective. 

·

 

Non-original spare parts or replacement parts were used. 

·

 

The unit was not operated within the permissible technical parameters. 

·

 

Unauthorised constructional changes were made to the unit or if parts of the unit 
that may not be opened were dismantled. 

 

Summary of Contents for WOS

Page 1: ...ing manual WOS water oil separator Please read the following instructions carefully before installing separator unit into service Trouble free and safe operating of the unit can only be guaranteed if...

Page 2: ...oil 2 Depressurization chamber with air filter 3 First stage chamber 4 Condensate flow 5 Oil filter cartridge 6 Condensate flow water residual oil traces 7 Activated carbon filter cartridge final oil...

Page 3: ...99 635 21 Max FAD Nm 3 min scfm 19 8 29 8 55 6 Max condensate flow l h 1 1 Max condensate volume per condensate drain single discharge is 0 250 ltr 2 Max operating temperature is 65 C but when temper...

Page 4: ...d Installation and operating manual for those ad ons Maximum temperature and pressure for assembled system is the lowest of any individual part The medium used may not have any corrosive components th...

Page 5: ...malfunction caused by the use of ungenuine parts is not covered by Warranty or Product Liability Advanced dimensioning For advanced dimensioning please use following equations m Max oil adsorption g F...

Page 6: ...evice Make sure that white filter element is inserted in chamber 1 and carbon filter element is inserted in chamber 2 Fill the device with clean water Connect device to the system Outlet must be conne...

Page 7: ...with oil indicating test paper For test set please contact us or your local distributor Damaged components are to be replaced by new ones If a marked degree of damage is found the entire vessel is to...

Page 8: ...Installation and operating manual 8 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega air...