Installation
·
Unpack the device
·
It is recommended to place the device near the wall. Test valve is located on front
side of the device.
·
Make sure that you have easy access to the front side of the device.
·
Take both bags (carbon and polypropylene) out and remove protection foil from both
filter bags. Then put the cartridge back in the device.
·
Make sure that white filter element is inserted in chamber 1 and carbon filter
element is inserted in chamber 2.
·
Fill the device with clean water!
·
Connect device to the system.
·
Outlet must be connected to the sewage system.
Warning
It is strongly recommended to fill the device with clean water at least 24h (we recommend
to fill water into cartridge 1 day before installation/service) before you start to drain
condensate into the separator. If you start to drain condensate into an empty device, filter
element
can get saturated instantly or efficiency may be decreased.