OMEGA AIR WOS Installation And Operating Manual Download Page 4

WOS - Installation and operating manual 

 4 

Safety instructions 

 

The relevant safety at work and accident prevention regulations, plus operating instructions, 

shall apply for operating the separator. The separator has been constructed in accordance 

with the generally recognized rules of engineering. 

Ensure that installation complies with local laws and directives. 

Operator/user of the separator should make himself familiar with the function, installation 

and start-up of the unit. All the safety information is always intended to ensure your 

personal safety. 

·

 

Do not apply pressure to the separator. 

·

 

The permissible working temperatures and pressures for ad-on parts and separator 

elements are given under “Technical data sheet” and “Installation and operating 

manual” for those ad-ons. Maximum temperature and pressure for assembled 

system is the lowest of any individual part. 

·

 

The medium used may not have any corrosive components that could attack the 
materials of the separator in a way that is not permitted. Do not use the separator in 
hazardous areas with potentially explosive atmospheres. 

·

 

All installation and maintenance work on the separator may only be carried out by 

trained and experienced specialists. 

·

 

It is forbidden to carry out any kind of work on the separator and piping, including 

welding and constructional changes, etc. 

·

 

Depressurize the system before carrying out the installation work. 

·

 

Use original spare parts only. 

·

 

Use the device for appropriate purpose only. 

·

 

There shouldn’t be any tension between separator and installation. Separator 

shouldn’t be subject to any stress, vibration or other influence that could cause 

damage to the unit. 

 

 

Summary of Contents for WOS

Page 1: ...ing manual WOS water oil separator Please read the following instructions carefully before installing separator unit into service Trouble free and safe operating of the unit can only be guaranteed if...

Page 2: ...oil 2 Depressurization chamber with air filter 3 First stage chamber 4 Condensate flow 5 Oil filter cartridge 6 Condensate flow water residual oil traces 7 Activated carbon filter cartridge final oil...

Page 3: ...99 635 21 Max FAD Nm 3 min scfm 19 8 29 8 55 6 Max condensate flow l h 1 1 Max condensate volume per condensate drain single discharge is 0 250 ltr 2 Max operating temperature is 65 C but when temper...

Page 4: ...d Installation and operating manual for those ad ons Maximum temperature and pressure for assembled system is the lowest of any individual part The medium used may not have any corrosive components th...

Page 5: ...malfunction caused by the use of ungenuine parts is not covered by Warranty or Product Liability Advanced dimensioning For advanced dimensioning please use following equations m Max oil adsorption g F...

Page 6: ...evice Make sure that white filter element is inserted in chamber 1 and carbon filter element is inserted in chamber 2 Fill the device with clean water Connect device to the system Outlet must be conne...

Page 7: ...with oil indicating test paper For test set please contact us or your local distributor Damaged components are to be replaced by new ones If a marked degree of damage is found the entire vessel is to...

Page 8: ...Installation and operating manual 8 OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega air...

Reviews: