CKL-CHP - Installation and operating manual 

 

A pressure gauge, which shows the operational pressure, must be installed in the 
unit, respectively in the pipeline. 

 

Depressurize the system before carrying out the installation work. The unit must be 
installed vertically in the piping. 

 

Ensure that separator is installed without any stresses. 

 

Use original spare parts only. 

 

Use the device for appropriate purpose only. 

Appropriate use 

 CKL-CHP series cyclone separators are designed for high efficient removal of bulk 
liquids from compressed air and vacuum systems. This appliance must be used 
only for the purpose for which it was specifically designed. All other uses are to be 

considered incorrect and will void warranty. 

Specifically: 

 

cyclone can only be used for “GROUPE 2” fluids (PED 2014/68/EU). 

 

cyclone can not be used for explosive, toxic, flammable, corrosive and “GROUPE 1” 
fluids (PED 2014/68/EU). 

Warning: internal corrosion can seriously reduce the safety of installation: check it during 
changing the cartridge. 

The manufacturer will under no circumstances be responsible for any damage resulting from 
improper, incorrect or unreasonable use. 

Use genuine spare parts only. Any damage or malfunction caused by the use of ungenuine 
parts is not covered by Warranty or Product Liability. 

 

Summary of Contents for CKL

Page 1: ...CHP compressed air condensate separator Please read the following instructions carefully before installing cyclone housing unit into service Trouble free and safe operating of the unit can only be gua...

Page 2: ...s a condensate separator element This element separates already liquefied water from mainstream and prevents the liquids and large particles from being airborne again To discharge condensate from the...

Page 3: ...ar g 20 C CORRECTION FACTORS To calculate the correct capacity of a given cyclone based on actual operating conditions multiply the nominal flow capacity by the appropriate correction factor s CORRECT...

Page 4: ...operating pressure or operating temperature range see data label The permissible working temperatures and pressures for ad on parts and separator elements are given under Technical data for those ad...

Page 5: ...and vacuum systems This appliance must be used only for the purpose for which it was specifically designed All other uses are to be considered incorrect and will void warranty Specifically cyclone can...

Page 6: ...CKL CHP Installation and operating manual 6 Installation 1 p 0 bar 2 3 4 5 1 2 6 7 O ring back up ring 8 1 2 9 10 1 2...

Page 7: ...st ensure safety and reliably operation Cyclone must be protected against injuries and non authorized substitution Operating pressure must correspond to design pressure Cyclone must be connected to pi...

Page 8: ...he maintenance work has been finished Warranty exclusion The guarantee shall be void if The operating instructions were not followed with respect to initial commissioning and maintenance The unit was...

Reviews: