CKL-CHP - Installation and operating manual 

PRESSURE EQUIPMENT DIRECTIVE PED 2014/68/EU (Fluid group 1) 

Size 

PED Category 

003 - 047 

Category 3, Module H 

094 

Category 4, Module H1 

 

There is Technical datasheet available. For additional technical specification, contact 
manufacturer. 

 

Safety instructions 

The relevant safety at work and accident prevention regulations, plus operating instructions, 
shall apply for operating the cyclone. The cyclone has been constructed in accordance with 
the generally recognized rules of engineering. It complies with the requirements of directive 
PED 2014/68/EU concerning pressure equipment. 

Ensure that installation complies with local laws for operation and routine testing of 
pressure equipment at the place of installation. 

Operator/user of the cyclone should make himself familiar with the function, installation and 
start-up of the unit. All the safety information is always intended to ensure your personal 
safety. 

 

Do not exceed max. operating pressure or operating temperature range (see data 
label). 

 

The permissible working temperatures and pressures for ad-on parts and separator 
elements are given under Technical data for those ad-ons. Maximum temperature 
and pressure for assembled system is the lowest of any individual part. 

 

It is necessary to ensure that the unit is equipped with the corresponding safety and 
test devices to prevent the permissible operating parameters from being exceeded. 

 

Separator has been designed for a primarily static pressure. Rapid changes of 
pressure are not allowed. 

 

Ensure that the separator is not subject to vibrations that could cause fatigue 
fractures. 

 

Separator is not to be subjected to mechanical stresses. 

 

The medium used may not have any corrosive components that could attack the 
materials of the separator in a way that is not permitted. Do not use the separator in 
hazardous areas with potentially explosive atmospheres. 

 

All installation and maintenance work on the separator may only be carried out by 
trained and experienced specialists. 

 

It is forbidden to carry out any kind of work on the cyclone, including welding and 
constructional changes, etc. 

Summary of Contents for CKL

Page 1: ...CHP compressed air condensate separator Please read the following instructions carefully before installing cyclone housing unit into service Trouble free and safe operating of the unit can only be gua...

Page 2: ...s a condensate separator element This element separates already liquefied water from mainstream and prevents the liquids and large particles from being airborne again To discharge condensate from the...

Page 3: ...ar g 20 C CORRECTION FACTORS To calculate the correct capacity of a given cyclone based on actual operating conditions multiply the nominal flow capacity by the appropriate correction factor s CORRECT...

Page 4: ...operating pressure or operating temperature range see data label The permissible working temperatures and pressures for ad on parts and separator elements are given under Technical data for those ad...

Page 5: ...and vacuum systems This appliance must be used only for the purpose for which it was specifically designed All other uses are to be considered incorrect and will void warranty Specifically cyclone can...

Page 6: ...CKL CHP Installation and operating manual 6 Installation 1 p 0 bar 2 3 4 5 1 2 6 7 O ring back up ring 8 1 2 9 10 1 2...

Page 7: ...st ensure safety and reliably operation Cyclone must be protected against injuries and non authorized substitution Operating pressure must correspond to design pressure Cyclone must be connected to pi...

Page 8: ...he maintenance work has been finished Warranty exclusion The guarantee shall be void if The operating instructions were not followed with respect to initial commissioning and maintenance The unit was...

Reviews: