CKL-CHP - Installation and operating manual
4
PRESSURE EQUIPMENT DIRECTIVE PED 2014/68/EU (Fluid group 1)
Size
PED Category
003 - 047
Category 3, Module H
094
Category 4, Module H1
There is Technical datasheet available. For additional technical specification, contact
manufacturer.
Safety instructions
The relevant safety at work and accident prevention regulations, plus operating instructions,
shall apply for operating the cyclone. The cyclone has been constructed in accordance with
the generally recognized rules of engineering. It complies with the requirements of directive
PED 2014/68/EU concerning pressure equipment.
Ensure that installation complies with local laws for operation and routine testing of
pressure equipment at the place of installation.
Operator/user of the cyclone should make himself familiar with the function, installation and
start-up of the unit. All the safety information is always intended to ensure your personal
safety.
Do not exceed max. operating pressure or operating temperature range (see data
label).
The permissible working temperatures and pressures for ad-on parts and separator
elements are given under Technical data for those ad-ons. Maximum temperature
and pressure for assembled system is the lowest of any individual part.
It is necessary to ensure that the unit is equipped with the corresponding safety and
test devices to prevent the permissible operating parameters from being exceeded.
Separator has been designed for a primarily static pressure. Rapid changes of
pressure are not allowed.
Ensure that the separator is not subject to vibrations that could cause fatigue
fractures.
Separator is not to be subjected to mechanical stresses.
The medium used may not have any corrosive components that could attack the
materials of the separator in a way that is not permitted. Do not use the separator in
hazardous areas with potentially explosive atmospheres.
All installation and maintenance work on the separator may only be carried out by
trained and experienced specialists.
It is forbidden to carry out any kind of work on the cyclone, including welding and
constructional changes, etc.