CKL-CHP - Installation and operating manual 

Maintenance 

 

To prevent air leakage and malfunction replace housing O-ring if necessary. For 
replacement contact manufacturer. 

 

Damaged components are to be replaced by new ones. If a marked degree of 
damage is found, the entire cyclone is to be replaced.  

 

Cyclone has been designed for a life of 10 years in normal operating environment. 
After 10 years periodical checks of cyclone integrity are strongly recommended for 
safe operation. 

 

Carry out a check for leaks once the maintenance work has been finished. 

Warranty exclusion 

The guarantee shall be void if: 

 

The operating instructions were not followed with respect to initial commissioning 
and maintenance. 

 

The unit was not operated properly and appropriately. 

 

The unit was operated when it was clearly defective. 

 

Non-original spare parts or replacement parts were used. 

 

The unit was not operated within the permissible technical parameters. 

 

Unauthorised constructional changes were made to the unit or if parts of the unit 
that may not be opened were dismantled. 
 
 
 
 
 
 
 
 
 
 
 
 
 

OMEGA AIR d.o.o. Ljubljana 

Cesta Dolomitskega odreda 10 

SI-1000 Ljubljana, Slovenia 

Tel.: +386 (0)1 200 68 00 

Fax.: +386 (0)1 200 68 50 

E-mail[email protected] 

www.omega-air.si 

Summary of Contents for CKL

Page 1: ...CHP compressed air condensate separator Please read the following instructions carefully before installing cyclone housing unit into service Trouble free and safe operating of the unit can only be gua...

Page 2: ...s a condensate separator element This element separates already liquefied water from mainstream and prevents the liquids and large particles from being airborne again To discharge condensate from the...

Page 3: ...ar g 20 C CORRECTION FACTORS To calculate the correct capacity of a given cyclone based on actual operating conditions multiply the nominal flow capacity by the appropriate correction factor s CORRECT...

Page 4: ...operating pressure or operating temperature range see data label The permissible working temperatures and pressures for ad on parts and separator elements are given under Technical data for those ad...

Page 5: ...and vacuum systems This appliance must be used only for the purpose for which it was specifically designed All other uses are to be considered incorrect and will void warranty Specifically cyclone can...

Page 6: ...CKL CHP Installation and operating manual 6 Installation 1 p 0 bar 2 3 4 5 1 2 6 7 O ring back up ring 8 1 2 9 10 1 2...

Page 7: ...st ensure safety and reliably operation Cyclone must be protected against injuries and non authorized substitution Operating pressure must correspond to design pressure Cyclone must be connected to pi...

Page 8: ...he maintenance work has been finished Warranty exclusion The guarantee shall be void if The operating instructions were not followed with respect to initial commissioning and maintenance The unit was...

Reviews: