20160

80

MATERIALS 

Housing material 

PA6 (Polyamide) 30% glass fibres, Brass, Steel 

Sealing 

NBR 

Safety instructions 

 

 

Depressurize the system before carrying out any work on the piping. 

 

Installation and maintenance work may only be carried out when the device is not under 

pressure. 

 

Installation and maintenance work may only be carried out by trained and experienced staff. 

 

Do not exceed max. operating pressure or operating temperature range (see data label). 

 

Do not use the device in hazardous areas with potentially explosive atmospheres. 

 

Use original spare parts only. 

 

Use the device for the appropriate purpose only. 

 Appropriate use 

AOK16B series condensate drain is intended exclusively for the following purpose: 

 

Draining condensate from compressed air system (cyclone condensate separator, air 

filters). 

Any other form of use or one going beyond this shall be considered as inappropriate. We shall have 
no liability whatsoever for any damage incurred as a result. 

Installation 

 

AOK16B is easy to install inside of the filter housing. 

Install the AOK16B at a level below the receiver, if not the receiver will fill up with condensate. 

After initial run, open AOK16B and clean all components. 

It is strongly recommended that waste condensate from discharge port is connected to water 
treatment application, such as WOSm series water oil separator to protect the environment from 
pollution and to comply with environmental laws. 

 

 

Summary of Contents for AOK16B

Page 1: ... Please read the following instructions carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this manual are respected 20160803 AOK16B ...

Page 2: ...stem drop under the 0 1 bar the condensate drain opens and venting all accumulated condensate Manual action condensate can be drained off by push up lower brass part of the drain Components Technical data Part 1 Enclosure 2 Float 3 Shutter 4 Needle 5 Cylinder 6 Thread carrier 7 Spring 8 Discharge 9 O ring 10 Needle holder Operation temperature range 1 5 65 C 35 149 F Operation pressure range 0 20 ...

Page 3: ... only Appropriate use AOK16B series condensate drain is intended exclusively for the following purpose Draining condensate from compressed air system cyclone condensate separator air filters Any other form of use or one going beyond this shall be considered as inappropriate We shall have no liability whatsoever for any damage incurred as a result Installation AOK16B is easy to install inside of th...

Page 4: ...parts Replacement sealings are available on demand Please contact your distributor or manufacturer Warranty exclusion The guarantee shall be void if The installation and operating manual was not followed with respect to installation initial commissioning and maintenance The unit was not operated properly and appropriately The unit was operated when it was clearly defective Non original spare parts...

Reviews: