background image

Printed in Canada 7214430100R00

Replacement Parts

1     Baseplate

2     Motor Assembly

3     Heating Element

4     Inlet Grill

5     Element Housing

6     Circuit Board

8     Sensor

9     Nozzle

10     Nameplate

11    Cover

12    Fasteners

12

13    Sensor Mounting Plate

INSTALLATION

DIMENSIONS

Installation must be performed by qualified personnel.

Hand dryer must be grounded.

· Remove the two tamper-proof cover attachment screws using the 

supplied key. Tilt the cover outward and unhook at the top.

· All dryers must be fed by two power conductors and one ground 

wire. For wall wiring, carry the electrical wire to the dryer and attach 

it to the baseplate knockout using an approved connector.
· Attach the baseplate firmly to the wall. For wood walls or wood 

studs, use minimumb No. 12 screws of proper length to ensure 

25mm (1”) minimum stud penetration. For masonry walls use 

expansion bolts or anchors for 6mm (1/4”) screws of proper length 

to ensure penetration 6mm (1/4”) deeper than anchor. Shim if 

necessary to ensure that the baseplate is level and flat against the 

wall.
· For surface wiring, remove the knockouts from the dryer inlet grill 

and the outlet grill bracket and bring the conduit to the dryer from 

below. Attach the conduit to the outlet grill bracket using an 

approved connector.
· Connect the two power leads to the terminal block on the circuit 

board. Tug gently on the wires to ensure that they are held tightly. 

Attach the ground wire securely to the ground screw on the 

wallplate.
· Replace the dryer cover. Hook the cover onto the two cap screws 

at the top and pivot the bottom of the cover over the metal tabs on 

the inlet grill. Replace the two tamper-proof screws, taking care not 

to cross-thread or over-tighten them.

· IMPORTANT: After turning on electrical power, wait 5 seconds 

before attempting to operate dryer.

Cleaning & Maintenance

-

 Regularly clean exterior surfaces and wash with mild soap.

- Remove accumulated dust from air inlet areas.

- Ensure that infrared sensor lens is clean and unobstructed.

Once per year, or more frequently if dryer is installed in a 

dusty, greasy, or heavy use environment:

C

US

7     Outlet Grill

Distance from bottom edge of dryer to floor:

Men

. . . . . . . . . . . . . . . . . . 47 in . . . . 119 cm

Women

. . . . . . . . . . . . . . . . . . 44 in . . . . 112 cm

Children  8-10 years
Children 11-13 years

. . . . . . . . . . 38 in . . . . . 97cm

Children 14-16 years

. . . . . . . . . . 44 in . . . . 112 cm

ADA Compliant. . . . . . . . . . . . . . . . . 36 in . . . . . 91 cm

. . . . . . . . . . 35 in . . . . . 89 cm

6 ¾” - 172mm

11” - 279mm

Steel - 9-1/8” - 232mm

14    

15    

2-25 boul. Maisonneuve,  St-Jérôme,  Québec   J5L 0A1 Canada
Tel: 1(855) 550-0303 Tel: 1(450)432-5946 

Fax. 

1 (450) 432-8910

www.

comaccorporation.com

[email protected]

· Use the chart below to determine the correct height of the base-

plate. When two or more dryers are installed, they should be placed 

no closer than 60cm (24”) between centers. Mark the location of the 

four mounting holes.

i.

BLAST

series

- IMPORTANT: 

Turn off the breaker at electrical panel or source.

- Remove cover.

- Remove accumulated dust from mechanism.

- Replace cover and restore power.

IMPORTANT: 

It takes up to 3 minutes after power-on till hand dryer 

be ready to operate. When device turns on, it tries to connect to the 

network for two times and each times it takes up to 90 seconds. If 

device is not able to connect to the network , the modem turns off 

and device works as a standard hand dryer

Sim Card
Antenna