Description 

 
AOK16B has been developed for fully automatic discharging of condensate 
or any other non-aggressive fluid from compressed air system.  AOK16B is 
easy to install inside to the filter housing. The drain can run in three different 
ways. Automatic action-  condensate accumulates in the filter housing and 
when the level is high enough condensate is being automatically discharged 
from the system. Servo acting valve is operated by precise level controlled 
floater which assures reliable and efficient operation. Semi-automatic 
action- when the pressure in system drop under the 0,1 bar the condensate 
drain opens and venting all accumulated condensate.  Manual action- 
condensate can be drained off by push up lower brass part of the drain. 

Components 

 

 

 

 

 

 

 

 

 

Technical data 

 

 

 

 

 

Part

 

Enclosure 

Float 

Shutter 

Needle 

Cylinder 

Thread carrier 

Spring 

Discharge 

O - ring 

10 

Needle holder 

Operation temperature range 

1,5 -

65 ⁰C 

 

 35 – 

149 ⁰F

 

Operation pressure range 

0 – 20 bar  

0 – 290 psi 

Recommended operating pressure 

1,5 – 16 bar (g) 

22 - 232 psi 

Minimum automatic acting pressure 

0,3 bar (g)  

 4,3 psi 

Operating media 

Condensate (air, water, oil); Non-aggressive 

Connection 

G ½” 

Discharge connection 

φ8mm

 

Mass 

0,04 kg 

Dimensions A x B [mm] 

90 x 38,5 

Valve type 

Servo acting, normally closed 

*Leakage (at 1,5 bar): 500cm

3

 air/hour (at higher pressure leakage decreases)

 

Summary of Contents for AOK16B

Page 1: ... Please read the following instructions carefully before installing the product Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this manual are respected 20160803 AOK16B ...

Page 2: ...stem drop under the 0 1 bar the condensate drain opens and venting all accumulated condensate Manual action condensate can be drained off by push up lower brass part of the drain Components Technical data Part 1 Enclosure 2 Float 3 Shutter 4 Needle 5 Cylinder 6 Thread carrier 7 Spring 8 Discharge 9 O ring 10 Needle holder Operation temperature range 1 5 65 C 35 149 F Operation pressure range 0 20 ...

Page 3: ... only Appropriate use AOK16B series condensate drain is intended exclusively for the following purpose Draining condensate from compressed air system cyclone condensate separator air filters Any other form of use or one going beyond this shall be considered as inappropriate We shall have no liability whatsoever for any damage incurred as a result Installation AOK16B is easy to install inside of th...

Page 4: ...parts Replacement sealings are available on demand Please contact your distributor or manufacturer Warranty exclusion The guarantee shall be void if The installation and operating manual was not followed with respect to installation initial commissioning and maintenance The unit was not operated properly and appropriately The unit was operated when it was clearly defective Non original spare parts...

Reviews: