2
20160
80
3
Description
AOK16B has been developed for fully automatic discharging of condensate
or any other non-aggressive fluid from compressed air system. AOK16B is
easy to install inside to the filter housing. The drain can run in three different
ways. Automatic action- condensate accumulates in the filter housing and
when the level is high enough condensate is being automatically discharged
from the system. Servo acting valve is operated by precise level controlled
floater which assures reliable and efficient operation. Semi-automatic
action- when the pressure in system drop under the 0,1 bar the condensate
drain opens and venting all accumulated condensate. Manual action-
condensate can be drained off by push up lower brass part of the drain.
Components
Technical data
Part
1
Enclosure
2
Float
3
Shutter
4
Needle
5
Cylinder
6
Thread carrier
7
Spring
8
Discharge
9
O - ring
10
Needle holder
Operation temperature range
1,5 -
65 ⁰C
35 –
149 ⁰F
Operation pressure range
0 – 20 bar
0 – 290 psi
Recommended operating pressure
1,5 – 16 bar (g)
22 - 232 psi
Minimum automatic acting pressure
0,3 bar (g)
4,3 psi
Operating media
Condensate (air, water, oil); Non-aggressive
Connection
G ½”
Discharge connection
φ8mm
Mass
0,04 kg
Dimensions A x B [mm]
90 x 38,5
Valve type
Servo acting, normally closed
*Leakage (at 1,5 bar): 500cm
3
air/hour (at higher pressure leakage decreases)