9
4.
When we finish with the installation of the components, it is necessary to tighten the nuts with
specified torque. The torque value is defined in the table beside the fig. It is very recommended
that all nuts(3) are equally a deep screwed into studs(1).
Maintenance
•
Damaged components are to be replaced by new ones. If a marked degree of damage is found, the
entire assembly kit is to be replaced.
•
Assembly kit has been designed for a life of 10 years in normal operating environment. After 10
years periodical checks of filter integrity are strongly recommended for safe operation.
•
Carry out a check for leaks once the maintenance work has been finished.
Warranty exclusion
The guarantee shall be void if:
•
The operating instructions were not followed with respect to initial commissioning and
maintenance.
•
The unit was not operated properly and appropriately.
•
The unit was operated when it was clearly defective.
•
Non-original spare parts or replacement parts were used.
•
The unit was not operated within the permissible technical parameters.
•
Unauthorised constructional changes were made to the unit or if parts of the unit that may not
be opened were dismantled.
Type
Torque
0006-0016
2,5 N/m
0026-0106
5 N/m
0186-0706
10 N/m