Operation
packing cycle.
• The actual vacuum pressure is indicated by the analog vacuum gauge.
PLUG AND PLAY
• When turning on the machine for the first time:
- Running time of the vacuum pump is pre-set at 30-40 seconds and the sealing time at 2 seconds.
Vacuum is indicated on the analog vacuum gauge.
• When turning on the machine after that, program P1 will contain the most-recently used settings.
• The vacuum and sealing times are easily adjusted to match the needs for the application.
OPERATING THE MACHINE WITH ONE-PROGRAM CONTROL SYSTEM
On: turns the machine on:
• The machine will start up in the most-recently used program.
• The pump of a machine with a transparent cover will start when the cover is closed.
Off: turns the machine off:
• When pressing the button once, the symbol will start blinking and the pump will stop
after about 4 seconds.
• When pressing the button a second time, the pump will stop immediately.
• Closing the cover will initiate the cool-down phase; the machine will complete a number of
vacuum cycles before turning off automatically.
Stop-function:
• Stops the machine at any point in the packing cycle and aerates the chamber.
Reset-function:
• While programming, resets the program value to its original setting.
Press the menu button to return to the home menu.
Stops the current function and initiates the next step in the cycle:
• By pressing the of the sealing button , the vacuum function stops and the program jumps
to the sealing function.
• While packing sauce or soup, the package may be sealed as soon as product boiling is
detected.
Entering the desired vacuum time :
By pressing the + or – of the vacuum button, the vacuum time can be increased or decreased.
The selected value is confirmed and saved by pressing the menu button :
• Press the button to reset the original value.
Entering the desired sealing time :
• By pressing the + or – of the sealing button, the sealing time can be increased or decreased.
The selected value is confirmed and saved by pushing the menu button :
• Press the button to reset the original value.
Summary of Contents for VP-NL-0004-SN
Page 21: ...21 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Overall...
Page 22: ...22 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Vacuum Chamber...
Page 23: ...23 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Lid...
Page 24: ...24 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Hinge...
Page 25: ...25 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Air Valve...
Page 26: ...26 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Sealbeam...
Page 27: ...27 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 4m3 Transformer...