Operation
PROGRAMMING THE MACHINE
ONE-PROGRAM CONTROL SYSTEM
• The one-program control system is standard on the S20, S30, S40, S50, M10, M30 (with 21m
3
pump).
• The one-program control system is time-based.
• The ten-program control system (time or sensor) is optional for these models, except for S20.
The ONe-PrOgrAm CONTrOL SySTem PrOVIdeS ONLy ONe PrOgrAm (P1)
• There is no memory to store additional values.
• The machine starts with the values that were most-recently used.
• The pump starts upon closing of the cover and stops when it is reopened.
PROGRAMMABLE FUNCTIONS
The following function values may be customized for P1:
• Vacuum time: in seconds.
• Sealing time: in seconds.
PROGRAMMING
1. Turn the machine on by pressing the on/off button.
a. The factory setting for the vacuum time is 30-40 seconds.
b. The factory settings for the seal time is 2 seconds.
REVIEWING VACUUM TIME AND SEALING TIME
1. Press the button to display the programmed vacuum time the vacuum time is pre-set at the factory.
2. Press the button to display the programmed sealing time the sealing time is pre-set at the factory at 2
seconds.
ADjUSTING VACUUM TIME FOR P1
1. Press twice on the or button.
- After pressing once, the programmed value is displayed.
- After pressing twice, the symbol will start blinking and the value may be adjusted.
2. Save the new value by pressing the menu button.
3. To retain the original value, press the button.
4. Exit the program by pressing the menu button.
ADjUSTING SEALING TIME FOR P1
1. Press twice on the or button.
- After pressing once, the programmed value is displayed.
- After pressing twice, the symbol will start blinking and the value may be adjusted.
2. Save the new value by pressing the menu button.
3. To retain the original value, press the button.
4. Exit the program by pressing the menu button.
Summary of Contents for VP-NL-0004-SN
Page 21: ...21 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Overall...
Page 22: ...22 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Vacuum Chamber...
Page 23: ...23 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Lid...
Page 24: ...24 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Hinge...
Page 25: ...25 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Air Valve...
Page 26: ...26 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Sealbeam...
Page 27: ...27 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 4m3 Transformer...
Page 28: ...28 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 8m3 Transformer...
Page 29: ...29 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Control Panel...
Page 43: ...43 Electrical Schematics Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007...