![Omcan VP-NL-0004-SN Instruction Manual Download Page 10](http://html1.mh-extra.com/html/omcan/vp-nl-0004-sn/vp-nl-0004-sn_instruction-manual_4168225010.webp)
10
Operation
• When operating a packaging machine with a sensor-based program, the actual vacuum pressure is digitally
shown on the LCD display in mbar (standard setting) or in % vacuum.
PLUG AND PLAY
• When turning on a sensor-based machine for the first time, it will start up in the PA program AUTOMATIC.
This is a pre-set factory program with 5 mbar of vacuum and 2 seconds of sealing time.
• When turning on the machine after that, it will start up in the most-recently used program.
OPTIONAL INSTALLATION OF SOFT-AIR
• The soft-air feature can also be installed at a later date by ordering the optional soft-air kit.
OPERATING THE MACHINE WITH TEN-PROGRAM CONTROL SYSTEM
On: turns the machine on:
• The machine will start up in the most-recently used program.
• The pump of a machine with a transparent cover will start when the cover is closed.
Off: turns the machine off:
• When pressing the button once, the symbol will start blinking and the pump will stop
after about 4 seconds.
• When pressing the button a second time, the pump will stop immediately.
• Closing the cover will initiate the cool-down phase.
• The machine will complete a number of vacuum cycles before turning off automatically.
Stop-function:
• Stops the machine at any point in the cycle and aerates the chamber.
Reset-function:
• While programming, resets the program value to its original setting.
• Press the menu button to return to the home menu.
Back function:
• While reviewing programmed values, returns to the previous selection.
Stops the active function and initiates the next step in the cycle:
• While the machine is running, exits the active function and jumps to the next step in the cycle.
• While packing sauce or soup, the package may be sealed as soon as product boiling is
detected.
Menu button:
• Toggles between home menu and settings menu .
• Save function: during programming, confirms and saves the entered program values and
returns to the home menu.
• Return function: returns to the home menu.
review program values:
• Cycles through programs P1 to P9, as well as PA and P H2O.
• Displays the programmed value for each function; the function being reviewed will be
blinking.
• Displays the value for the next function.
• Returns to the home menu.
Summary of Contents for VP-NL-0004-SN
Page 21: ...21 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Overall...
Page 22: ...22 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Vacuum Chamber...
Page 23: ...23 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Lid...
Page 24: ...24 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Hinge...
Page 25: ...25 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Air Valve...
Page 26: ...26 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Sealbeam...
Page 27: ...27 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 4m3 Transformer...
Page 28: ...28 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 8m3 Transformer...
Page 29: ...29 Parts Breakdown Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007 Control Panel...
Page 43: ...43 Electrical Schematics Model VP NL 0004 SN 59006 Model VP NL 0008 SN 59007...