Troubleshooting
If your appliance develops a fault, please check the following table before call Omcan.
Fault
Probable Cause
Action
Compressor Not
Running
Fuse blown or circuit breaker tripped.
Replace fuse or reset circuit breaker.
Power cord unplugged.
Plug in power cord.
Thermostat set too high.
Set thermostat to lower temperature.
Cabinet in defrost cycle.
Wait for defrost cycle to finish.
Condensing Units
Run For Long
Periods of Time
Excessive amount of warm product placed
in cabinet.
Allow adequate time for product to cool
down.
Dirty condenser coil.
Clean the condenser coil.
Evaporator coil iced over.
Unplug unit and allow coil to defrost. Make
sure thermostat is not set too cold. Ensure
that door gasket(s) are sealing properly.
Cabinet
Temperature is too
Warm
Thermostat set too warm.
Set thermostat to lower temperature.
Excessive amount of warm product placed
in cabinet.
Allow adequate time for product to cool
down.
Fuse blown or circuit breaker tripped.
Replace fuse or reset circuit breaker.
Dirty condenser coil.
Clean the condenser coil.
Evaporator coil iced over.
Ensure doors are closed when not in use.
Avoid opening doors for long periods of
time.