background image

6

safety and warranty

3.  Strong base, strong acid, organic solvent and corrosive goods or those are easy to pollute to food are 

prohibited storing in the cooler; otherwise, it can cause corrosiveness or accident.

4.  Don’t raise the cooler or the shell of the electric parts, or it will cause the decline in insulation and cause 

corrosion.

5.  When the cooler will be not be used for a long time, disconnect the power and clean it. Please examine the 

circuit whether it is ok before reuse.

6.  If the supply cord is damaged, it must be replaced by a special cord or assembly available from the 

manufacturer or its service agent.

7.  The appliance shall be disconnected from its power source during cleaning or maintenance and when 

replacing parts.

8. 

The A-weighted emission sound pressure level is below 60dB(A).

9. 

Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance.

10. Flammable blowing gas of the cooler should be handled according to local regulations. Before you scrap 

the appliance, please take off the doors to prevent children trapped.

CAUTION:

1. 

Risk of fire / flammable materials, taking care to avoid causing a fire by igniting flammable material.

2.  Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-

in.

3.  Do not use mechanical devices or other means to accelerate the defrosting process, other than those 

recommended by the manufacturer.

4.  Do not damage the refrigerant circuit.

5. 

Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of 

the type recommended by the manufacturer.

WARNING

1.  Do not, under any circumstances, cut or remove the third ground prong from the power cord supplied. This 

appliance is not designed to be used with an inverter. The cord should be secured behind the appliance 

and not left exposed or dangling to prevent accidental injury.

2. 

Never unplug the cooler by pulling the power cord. Always grip the plug firmly and pull straight out from the 

receptacle.

3. 

Do not use an extension cord with this appliance. If the power cord is too short, have a qualified electrician 

or service technician install an outlet near the appliance. Use of an extension cord can negatively affect the 

performance of the unit.

4.  Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is damaged, 

have it replaced by an authorized service center.

CAUTION FOR SAFETY

•  Warning! Do not damage the cooling fluid circuit.

•  Warning! Do not damage walls of the machine: the cooling fluid circuit may damage.

•  Warning! Do not use electrical appliances inside the food storage compartments of the appliance, unless 

they are of the type recommended by the manufacturer.

•  Warning! The equipment must not be used by persons (including children) whose physical, sensorial, or 

mental capacities are reduced, or who lack experience and know-how, unless they have been provided, by 

Summary of Contents for RE-CN-305

Page 1: ...Revised 08 10 2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Glass Door Refrigeration Models RE CN 305 215 145 Items 47460 47586 47563 Instruction Manual...

Page 2: ...f Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty R...

Page 3: ...causados por fugas de agua La garant a por fugas de agua queda anulada si la temperatura ambiente supera los 75 F y el 55 de humedad relativa y el desag e del aparato no est conectado directamente a...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...tados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o da os visible o oculto por favor anote en la factura antes de acepta...

Page 6: ...e defrosting process other than those recommended by the manufacturer 4 Do not damage the refrigerant circuit 5 Do not use electrical appliances inside the food storage compartments of the appliance u...

Page 7: ...e ignition due to incorrect parts The appliance is to be installed in accordance with the safety Notice Any person who is involved with working on or breaking into a refrigerant circuit should hold a...

Page 8: ...propriate fire extinguishing equipment shall be available on hand A dry chemical or CO2 fire extinguisher should be adjacent to the charging area No person carrying out work in relation to a REFRIGERA...

Page 9: ...ooler with a soft cloth with neutral soap or detergent RESIDENTIAL USERS vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in n...

Page 10: ...ental conditions To minimize the environmental effects on the unit s performance the Technical Specifications Model RE CN 305 RE CN 215 RE CN 145 Volume 285 L 10 1 cu ft 217 L 7 7 cu ft 140 L 4 9 cu f...

Page 11: ...f the shelves It is essential that the unit is levelled during operation so as to avoid possible ice formation on the evaporator s fins due to insufficient drainage of the condensates Tilt unit by 2 a...

Page 12: ...quently Open the door as little as possible Too much storage Take out part of the storage Leakage of refrigerant Repair at a qualified service center Thermostat does not work properly Change the therm...

Page 13: ...a voltage stabilizer Evaporator fan not running Fan switch defective Change the switch Fan switch terminal is not connected properly Connect the switch terminal or change a new terminal Notice the fo...

Page 14: ...14 Parts Breakdown Model RE CN 305 47460 Model RE CN 215 47586 Model RE CN 145 47563...

Page 15: ...for 47460 32 AN261 Top Fan Cover for 47460 10 AN248 Switch for 47460 23 Parts Breakdown Model RE CN 305 47460 Model RE CN 215 47586 Item No Description Position Item No Description Position Item No De...

Page 16: ...AN252 Glass Door for 47563 27 AN233 Compressor Cover Wire Steel for 47563 5 AN243 Compressor Plate for 47563 15 AN253 Front Cover of Bottom for 47563 28 AN234 Water Storage Box for 47563 6 AN244 Adju...

Page 17: ...17 Model RE CN 305 47460 Model RE CN 215 47586 Model RE CN 145 47563 Electrical Schematics...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: