background image

11

Installation

Operation

following are recommended:

• 

The unit is not to be placed near any kind of heat source.

•  The unit is not to be placed near or inside air streams produced by ventilation fans, open doors and/ or 

windows.

• 

The unit is not to be situated under a roof-mounted ventilation system.

•  The unit should have sufficient space to ‘breathe’ (always use the rear space to ensure minimum 

clearance).

• 

The unit should not be placed under direct sunlight.

• 

Keep all ventilation openings in the appliance enclosure or in the structure clear of obstruction.

•  In order to reduce fire hazard, the installation of this appliance must be carried out only by a suitably 

qualified person.

LEVELLING THE UNIT

Place the unit at the chosen location. Using a spirit level, check whether the unit is levelled in both directions. 

The spirit level can be placed on one of the shelves. It is essential that the unit is levelled during operation so 

as to avoid possible ice formation on the evaporator’s fins due to insufficient drainage of the condensates. Tilt 

unit by 2° angle for easy closing of door and drain.

• 

Do not insert cream or spray bottles inside the cooler.

•  Do not store explosive substances such as aerosol cans with flammable propellant in the cooler.

OPERATION OF THE TEMPERATURE CONTROL KNOB

1.  The temperature inside the cabinet can be controlled with the temperature control knob.

2.  The knob should be kept upright normally to adjust the temperature.

3.  If the temperature control knob is hard to move to its original setting, coins or other tools can be inserted 

into the groove to move.

Stop

Product will cease to work.

1

When the user does not need a colder temperature.

2
3
4

When in normal use.

5

When the user needs a colder temperature.

6

MAX

When the user needs a coldest temperature.

Note: the cooler should not work more than 24 hours in coldest function MAX, please turn the knob 

back to 4 in time.

Summary of Contents for RE-CN-305

Page 1: ...Revised 08 10 2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Glass Door Refrigeration Models RE CN 305 215 145 Items 47460 47586 47563 Instruction Manual...

Page 2: ...f Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty R...

Page 3: ...causados por fugas de agua La garant a por fugas de agua queda anulada si la temperatura ambiente supera los 75 F y el 55 de humedad relativa y el desag e del aparato no est conectado directamente a...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...tados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o da os visible o oculto por favor anote en la factura antes de acepta...

Page 6: ...e defrosting process other than those recommended by the manufacturer 4 Do not damage the refrigerant circuit 5 Do not use electrical appliances inside the food storage compartments of the appliance u...

Page 7: ...e ignition due to incorrect parts The appliance is to be installed in accordance with the safety Notice Any person who is involved with working on or breaking into a refrigerant circuit should hold a...

Page 8: ...propriate fire extinguishing equipment shall be available on hand A dry chemical or CO2 fire extinguisher should be adjacent to the charging area No person carrying out work in relation to a REFRIGERA...

Page 9: ...ooler with a soft cloth with neutral soap or detergent RESIDENTIAL USERS vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in n...

Page 10: ...ental conditions To minimize the environmental effects on the unit s performance the Technical Specifications Model RE CN 305 RE CN 215 RE CN 145 Volume 285 L 10 1 cu ft 217 L 7 7 cu ft 140 L 4 9 cu f...

Page 11: ...f the shelves It is essential that the unit is levelled during operation so as to avoid possible ice formation on the evaporator s fins due to insufficient drainage of the condensates Tilt unit by 2 a...

Page 12: ...quently Open the door as little as possible Too much storage Take out part of the storage Leakage of refrigerant Repair at a qualified service center Thermostat does not work properly Change the therm...

Page 13: ...a voltage stabilizer Evaporator fan not running Fan switch defective Change the switch Fan switch terminal is not connected properly Connect the switch terminal or change a new terminal Notice the fo...

Page 14: ...14 Parts Breakdown Model RE CN 305 47460 Model RE CN 215 47586 Model RE CN 145 47563...

Page 15: ...for 47460 32 AN261 Top Fan Cover for 47460 10 AN248 Switch for 47460 23 Parts Breakdown Model RE CN 305 47460 Model RE CN 215 47586 Item No Description Position Item No Description Position Item No De...

Page 16: ...AN252 Glass Door for 47563 27 AN233 Compressor Cover Wire Steel for 47563 5 AN243 Compressor Plate for 47563 15 AN253 Front Cover of Bottom for 47563 28 AN234 Water Storage Box for 47563 6 AN244 Adju...

Page 17: ...17 Model RE CN 305 47460 Model RE CN 215 47586 Model RE CN 145 47563 Electrical Schematics...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: