TRANSPORTATION

1. 

Take out packing and clean all the cabinet using warm water together with 5% of neutral soap then dry it 

with a soft-cloth; for the glass parts only use specific products, avoiding the use of water which can leave 

on the glass limestone residues.

2. 

Keep a distance from the wall of 10 cm at least. Please level the unit by settling the adjustable feet.

3. 

Cabinet must be installed on a perfectly even surface, far away from any heat source included sun ray.

4.  Do not install the unit in open places and do not expose it to rain.

CHOOSING THE INSTALLATION LOCATION

The unit is for indoor application only. Due to the fact that the unit has a glass door, its performance is highly 

influenced by environmental conditions. To minimize the environmental effects on the unit’s performance, the 

Technical Specifications

Model

RE-CN-305

RE-CN-215

RE-CN-145

Volume

285 L / 10.1 cu.ft.

217 L / 7.7 cu.ft.

140 L / 4.9 cu.ft.

Door Frame

PVC

Refrigerant

R600a / 1.69g

R600a / 1.48g

R600a / 1.27g

Temperature Range

0 - 10°C / 32 - 50°F

Max Ambient Temp Rat-

ing

24°C / 75°F

Electrical

110-120V / 60Hz / 1

Current

1.5A

1.3A

Power

150 W

130 W

Cooling System

Air Forced / Ventilated / No Frost

Lock/Key

Yes

Side LED Light

Yes

Casters

Yes

Number of Shelves

4

3

Dimensions

22.6” x 20.7” x 71.3”

575 x 525 x 1810mm

21.1” x 20.7” x 62.2”

535 x 525 x 1580mm

16.5” x 20.7” x 56.3”

420 x 525 x 1430mm

Packaging Dimensions

25.8” x 22.8” x 73.3”

655 x 580 x 1863mm

24.2” x 22.8” x 64.3”

615 x 580 x 1633mm

19.7” x 22.8” x 58.4”

500 x 580 x 1483mm

Weight

130.1 lbs. / 59 kgs.

114.6 lbs. / 52 kgs.

92.6 lbs. / 42 kgs.

Packaging Weight

143.3 lbs. / 65 kgs.

125.7 lbs. / 57 kgs.

101.4 lbs. / 46 kgs.

Item Number

47460

47586

47563

Summary of Contents for RE-CN-305

Page 1: ...Revised 08 10 2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Glass Door Refrigeration Models RE CN 305 215 145 Items 47460 47586 47563 Instruction Manual...

Page 2: ...f Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty R...

Page 3: ...causados por fugas de agua La garant a por fugas de agua queda anulada si la temperatura ambiente supera los 75 F y el 55 de humedad relativa y el desag e del aparato no est conectado directamente a...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...tados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o da os visible o oculto por favor anote en la factura antes de acepta...

Page 6: ...e defrosting process other than those recommended by the manufacturer 4 Do not damage the refrigerant circuit 5 Do not use electrical appliances inside the food storage compartments of the appliance u...

Page 7: ...e ignition due to incorrect parts The appliance is to be installed in accordance with the safety Notice Any person who is involved with working on or breaking into a refrigerant circuit should hold a...

Page 8: ...propriate fire extinguishing equipment shall be available on hand A dry chemical or CO2 fire extinguisher should be adjacent to the charging area No person carrying out work in relation to a REFRIGERA...

Page 9: ...ooler with a soft cloth with neutral soap or detergent RESIDENTIAL USERS vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in n...

Page 10: ...ental conditions To minimize the environmental effects on the unit s performance the Technical Specifications Model RE CN 305 RE CN 215 RE CN 145 Volume 285 L 10 1 cu ft 217 L 7 7 cu ft 140 L 4 9 cu f...

Page 11: ...f the shelves It is essential that the unit is levelled during operation so as to avoid possible ice formation on the evaporator s fins due to insufficient drainage of the condensates Tilt unit by 2 a...

Page 12: ...quently Open the door as little as possible Too much storage Take out part of the storage Leakage of refrigerant Repair at a qualified service center Thermostat does not work properly Change the therm...

Page 13: ...a voltage stabilizer Evaporator fan not running Fan switch defective Change the switch Fan switch terminal is not connected properly Connect the switch terminal or change a new terminal Notice the fo...

Page 14: ...14 Parts Breakdown Model RE CN 305 47460 Model RE CN 215 47586 Model RE CN 145 47563...

Page 15: ...for 47460 32 AN261 Top Fan Cover for 47460 10 AN248 Switch for 47460 23 Parts Breakdown Model RE CN 305 47460 Model RE CN 215 47586 Item No Description Position Item No Description Position Item No De...

Page 16: ...AN252 Glass Door for 47563 27 AN233 Compressor Cover Wire Steel for 47563 5 AN243 Compressor Plate for 47563 15 AN253 Front Cover of Bottom for 47563 28 AN234 Water Storage Box for 47563 6 AN244 Adju...

Page 17: ...17 Model RE CN 305 47460 Model RE CN 215 47586 Model RE CN 145 47563 Electrical Schematics...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: