7
Operation
Installation
Before using the machine, a complete cleaning of the machine must be performed. Before placing food in the
warmer, let the machine operate at desired temperature for 30 - 45 minutes. Food must already be cooked
and heated before placing in the machine. This machine is not designed to cook food. Check the temperature
inside the machine regularly. If the machine is placed in an area with high humidity, open the rear doors to stop
LIGHT BULB AND COVER INSTALLATION
Before installing the shelving of the machine, install the lights and its covers.
1. Slide the light bulb into the lower receptacle slot.
2. Slide the light bulb into the upper receptacle slot.
3. Turn the light bulb until it locks into place correctly fitting into the receptacles.
4. Put the light cover into the bracket to fix it in place. Start at the bottom, press the edge of the cover on the
inside of the bracket from the bottom to the top.
5. Repeat steps 1 to 4 for the other side.
CHANGING THE LIGHT BULB OR COVER
1. Remove the front doors and shelves.
2. Reverse the steps in the Light Bulb and Cover Installation process.
3. Install a new cover or bulb by following the steps listed in the Light Bulb and Cover Installation process.
SHELF BRACKETS, SUPPORT AND DOOR INSTALLATION
1. First install the light bulb and its cover. Follow the procedures mentioned above for this process.
2. Fix the shelf supports into the base and top of the unit.
3. Install the shelf brackets into the supports so that the locking tabs are pointing to the back of the unit.
4. Fix the taller doors to the front with the handles facing outwards.
5. Fix the shorter doors to the back so the handles face outwards.
NOTES
1. Unit must be placed on a solid and level surface.
2. Before using this machine, please make sure the machine is safely grounded.
3. The voltage supply must be correspond with the rated voltage of the warmer.
4. Each time before using the machine, add 0.6 liters (0.16 gallons) of water into the water tray of this
machine.
5. After connecting the machine to the power supply, the power indicator light will be on. Turn the heating
switch to select the desired temperature. Air convection will keep the desired temperature throughout the
machine.
6. If light is needed, use the light bulb type equipped with the machine.
7. After using, always clean the machine. For safety reasons, cut off power supply and unplug before any
cleaning.
8. If any abnormal objects, substances or noises are observed, turn the machine off and contact Omcan at
1-800-465-0234.