![background image](http://html1.mh-extra.com/html/omcan/ce-it-0500/ce-it-0500_instruction-manual_3965072008.webp)
8
Installation
MAXIMUM NUMBER OF OVERLAYABLE OVENS: 3
Remove any polystyrene protections and remove the protective film, avoiding the use of tools that can
damage the surfaces.
CONNECTION TO UTILITIES (ELECTRICAL CONNECTION)
The oven is supplied with a power cord without a plug. Connection to the electric network must be performed
by interposing a differential magneto-thermal switch with suitable characteristics, in which the minimum
opening distance between the contacts is at least 3 mm.
IN ADDITION, FOLLOW THESE INSTRUCTIONS:
• The mains socket must be easily accessible and must not require any oven handling.
•
The electrical connection must be easily accessible even after oven installation.
•
The distance between the oven and the socket must be such that it does not cause the power cord to
stretch. Furthermore, the cable itself must not be under the base of the oven.
•
In order to avoid risks, any damaged power cord must be replaced by technical assistance service or a
qualified technician.
GROUNDING
The system MUST be grounded.
In compliance with current regulations, it is mandatory to connect the equipment to an equipotential system
whose efficiency must be correctly checked according to the regulations in force. The connection is made on
the special terminal located at the back of the oven, with a cable with a minimum section of 10mm2.
Summary of Contents for CE-IT-0500
Page 23: ...23 Parts Breakdown Model CE IT 0500 46725...
Page 24: ...24 Model CE IT 0500 46725 Parts Breakdown...
Page 25: ...25 Model CE IT 0500 46725 Parts Breakdown...
Page 26: ...26 Model CE IT 0500 46725 Parts Breakdown...
Page 27: ...27 Model CE IT 0500 46725 Parts Breakdown...
Page 29: ...29 Model CE IT 0500 46725 Electrical Schematics...