COLLAUDI E CONTROLLI DA EFFETTUARE PRIMA
DELL’AVVIAMENTO
VERIFICHE MECCANICHE
·
Controllare che le funi siano in posizione corretta sulle pulegge;
·
Livellamento e allineamento macchina;
·
Fissaggio e serraggio bulloni, raccordi e connessioni;
·
Scorrimento libero delle parti mobili;
·
Pulizia delle varie parti della macchina;
·
Posizione delle protezioni.
VERIFICHE ELETTRICHE
·
Collegamenti corretti secondo gli schemi;
·
Messa a terra della macchina;
·
Funzionamento dei seguenti dispositivi:
- finecorsa di salita,
- finecorsa di allentamento funi.
- elettrovalvola dell’impianto oleodinamico.
VERIFICA IMPIANTO OLEODINAMICO
·
Presenza d’olio in quantità idonea nel serbatoio;
·
Assenza di trafilamenti;
·
Funzionamento cilindro.
N.B. In caso d’assenza d’olio, immettere nel serbatoio della centra-
lina la quantità di olio mancante.
Vedere la procedura nel capitolo 6: “MANUTENZIONE”.
VERIFICA DEL SENSO DI ROTAZIONE
del motore secondo la freccia posta sulla pompa della centralina,
mediante brevi avviamenti (ciascun avviamento deve durare al
massimo due secondi).
In caso di inconvenienti nel funzionamento dell’impianto oleodina-
mico vedere tabella “inconvenienti e rimedi” al capitolo 7.
PRELIMINARY TESTS AND INSPECTIONS BEFORE STARTING
MECHANICAL CHECKS
·
Check that the cables are in correct position on the pulleys;
·
Levelling and alignment;
·
Tightness of bolts, unions and connections;
·
Free movement of all moving parts;
·
Cleaning of the different machine parts;
·
Position of guards and protections.
ELECTRICAL CHECKS
·
Correct connections in accordance with wiring diagrams;
·
Earth connection of the lift;
·
The operation of:
- lifting limit switch,
- cable slackening limit switch,
- solenoid valve in the hydraulic system.
HYDRAULIC CHECKS
·
Make sure the reservoir is filled with sufficient oil;
·
Check for leaks;
·
Make sure the cylinder is working properly.
N.B. If there is insufficient oil, top up the reservoir to the correct le-
vel.
See chapter 6 “MAINTENANCE” for details of the procedure.
CHECKING MOTOR ROTATION DIRECTION
Check that the motor is turning as indicated by the arrow on the
control unit hydraulic pump; do this by running the machine mo-
mentarily (maximum 2 seconds to avoid damage).
If the hydraulic system is not working properly, consult the fault dia-
gnosis chart in chapter 7.
32
Summary of Contents for 526BLV
Page 1: ...I PONTE SOLLEVATORE A 4 COLONNE GB 4 POST LIFT 526BLV...
Page 2: ......
Page 42: ...Colonne Post 40...
Page 43: ...Traverse Crossbeams 41...
Page 44: ...Pedane Platforms 42...
Page 45: ...Cilindro Cylinder 43...
Page 46: ...Centralina oleodinamica K3 Oleodynamic control unit K3 44...
Page 47: ...Quadro elettrico trifase Three phase electric panel 45...
Page 52: ......