![OLYS MPPT15060 User Manual Download Page 9](http://html1.mh-extra.com/html/olys/mppt15060/mppt15060_user-manual_735843009.webp)
Parameter
Note: the parameters in the following table are 12V, 24V, 36V, 48V need to be multiplied by multiple.
Model
MPPT15060
System
voltage
12V/24V/36V/48V
Max
.
charge current
60A, 30A per channel
Max. input power of solar panel
12V:780W, 24V: 1560W, 36V: 2340W, 48V:3120W
Max. input voltage of solar panel
150V(At the lowest temperature
),
138V(25
℃
)
Battery
type
GEL
Sealed
Flooded
user
Overvoltage shut-off load
16V
Overvoltage shut-off charging
15.5V
Overvoltage recovery voltage
13.7V
Equalization charge
14.6V
no
14.8V
Boost 0.2V
Boost charge
14.4V
14.3V
14.7V
14-15V
Float charge
13.5V
13.8V
13.5V
13-14V
Boost charge recovery
13.2V
Low voltage recovery load output
12.5V
11.5V-12.5V
Low voltage protection
(
shut-off
load
)
11V
10.5V-11.5V
Equalization charge time
120min
Temperature compensation
-3mv/
℃
/2V
Load
work
mode
manual
,
light
control
+
time
contorl
,
Real-time timing control
Night
detection
voltage
6
V
Dry contact terminal output voltage
Same as battery voltage, current up to 2A
Display mode
LCD+LED
Communication
mode
RS
485,
RJ45 interface
Temperature sensor
(
optional
)
3
m
Working temperature
-20℃-55℃
Demension
330
mm
×232
mm
87.5
mm
×
Weight
5kg
SHENZHEN OLYS COMPANY LIMITED
Tel: 0086-755-29533796
E-mail: [email protected]
Address: 5 floor, B building of Sheng De Industrial Park,Lang Kou, Da Lang, Long
Hua New district, Shenzhen City, China