Set  boost charge voltage

K

3

K

1

K

2

K

1

K

2

value range:  12V battery: 14-15V  ,  24V battery: 28-30V,  36V battery: 42-45V,  48V battery: 56-60V 

K

1

K

2

value range : 12V battery: 13-14V,  24V battery: 26-28V, 36V battery: 39-42V,48V battery: 42-56V 

K

3

K

1

K

2

Vale range: 12V battery: 10.5-11.5V,  24V battery: 21.0V-23.0V, 36V battery: 31.5V-34.5V , 48V battery: 42.0V-46.0V 

K

3

K

1

K

2

K

1

K

2

K

1

K

2

K

1

K

2

K

1

K

2

Value range: 12V battery: 11.5V-12.5V ,  24V battery: 23.0V-25.0V, 36V battery: 34.5V-37.5V , 48V battery: 46.0V-49.0V

K

3

K

1

K

2

K

1

K

2

K

2

K

1

K

2

Sealed

 

battery

Flooded

 

battery

K

1

K

2

Custom definition

K

3

K

1

K

2

GEL battery

K

1

Parameter setting operation

In the battery voltage display interface, press the K3 button for 5 seconds to enter the parameter setting browsing interface 

(see < Parameter Settings Interface Browse >), and press K1 or K2 to cycle to the parameter interface you want to set. 

Short press K3 button (SET), display "SET" font flashes to indicate that you can start to change the current parameter, press

 K1 or K2  to modify the parameter value, and then press K3 button  (set button)  save the current settings, and the word "SET" will 

stop flashing, and  so on, you can set other parameters. Press K4 key to directly exit the current parameter setting interface.

Setting

 

battery

 

type

Set a precision of 0.1V, which increases or decreases 0.1V every time you press K1 or K2.

Indicates that the font "SET" flashes

Set floating charge voltage

Set a precision of 0.1V, which increases or decreases 0.1V every time you press K1 or K2.

Se low voltage protection voltage of  battery

Set a precision of 0.1V, which increases or decreases 0.1V every time you press K1 or K2.

Set load reconnection voltage

Set a precision of 0.1V, which increases or decreases 0.1V every time you press K1 or K2.

Summary of Contents for MPPT15060

Page 1: ...sure that the battery works in the best state and greatly prolong the service life of the battery 8 It has full automatic control such as overcharge overdischarge overload protection anti reverse protection and so on The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages It shall be used with vented or sealed VRLA lead acid batteries only Safety Recommend...

Page 2: ...irtight battery where gas may accumulate the place Warning high pressure is dangerous PV arrays may generate high open circuit voltages Disconnect circuit breakers or safety before wiring and be careful during wiring Note when installing the controller make sure that enough air flows through the heat sink of the controller and there is at least 150mm space above and below the controller to ensure ...

Page 3: ...afety accidents Connection cable the connection cable between the controller and the battery is as short as possible which can effectively reduce the cable loss and reduce the voltage difference Recommended cable specifications length 4m 8mm length 4m 10mm2 1 The controller has two solar panel input ports each with a maximum charging current of 30A It can be connected arbitrarily and the controlle...

Page 4: ...ntal stripes rolling up dynamically Load ON Load OFF Press K1 or K2 to cycle forward or backward to browse the current working parameters or set working status Battery voltage PV1 voltage PV2 voltage Charge current PV power Ambient temperature Charging capacity AH Charging capacity WH Parameter setting browsing In the battery voltage display interface press the K3 button for 5 seconds to enter the...

Page 5: ...erface Browse and press K1 or K2 to cycle to the parameter interface you want to set Short press K3 button SET display SET font flashes to indicate that you can start to change the current parameter press K1 or K2 to modify the parameter value and then press K3 button set button save the current settings and the word SET will stop flashing and so on you can set other parameters Press K4 key to dir...

Page 6: ...ashes press K1 or K2 key to change the number of minutes in a cycle 0 59 5 Press the K3 key again the SET and M icons stop flashing the load time is set and save the settings Dual period real time control mode Turn the page of the load working mode to the dual period real time control interface mode 5 1 Press the K3 key the H icon flashes the ON1 icon is on press K1 or K2 key to modify the cycle n...

Page 7: ... the battery voltage here otherwise The controller will report an error and the controller will not work Battery voltage Automatic identification Set night detection voltage The night detection voltage is the voltage of the solar panel when the load is turned on and output it needs to be used when the load working mode is set to pure light control or light control time control Charging capacity se...

Page 8: ...ror code is displayed and the buzzer alarms synchronously and the alarm continues until the error is corrected Press K4 to exit the wrong generation interface return to the main interface and turn off the buzzer Start timing If the error persists after 10s the alarm will continue Ring every 0 5 seconds for one minute rings once in 0 5 seconds and the full battery icon flashes rings once in 0 5 sec...

Page 9: ... Float charge 13 5V 13 8V 13 5V 13 14V Boost charge recovery 13 2V Low voltage recovery load output 12 5V 11 5V 12 5V Low voltage protection shut off load 11V 10 5V 11 5V Equalization charge time 120min Temperature compensation 3mv 2V Load work mode manual light control time contorl Real time timing control Night detection voltage 6V Dry contact terminal output voltage Same as battery voltage curr...

Reviews: