Installation instructions

Battery connection

Solar panel connection

System expansion

Warning

+

-

Relay

Load

2

FUSE

+

-

+

- +

- +

-

Pv1

P V

2

+

-

+

- +

- +

-

+

-

+

- +

- +

-

1.

The wiring order must be in the prescribed order, first connect the 

     battery, and then connect the solar panel. when you disconnect the controller 
     you must first disconnect the solar panel. then disconnect the battery, and the 
     two groups of solar panels are in no order. 
2.  Batteries and solar panels must be connected to fuses or circuit breakers.
      Recommended fuse specification:   Battery:120A,   Solar panels per channel: 60A
3.  In the process of operation and installation, the phenomenon of short circuit 
      of storage battery or solar panel is strictly prohibited.

Battery type

: controller can only use lead-acid batteries, lithium battery can not use

Battery voltage

: it can automatically adapt to 12V , 24V , 48V battery, if you need to

use 36V battery, you must set the battery voltage to 36V on the display screen. 

Batteries in series and in parallel

: if batteries need to be connected in series and 

parallel, ensure the capacity of each battery the voltage is basically the same. 

Mixed use of batteries of different specifications is not recommended, which can easily

lead to uneven charging of individual batteries, aging and damage ahead of time. 

Wiring method

: it is recommended to first connect the fuse or circuit breaker to the connection line, 

then fix the controller end, and finally connect to the battery to ensure that the battery is not allowed

 to short circuit in the whole process, otherwise it may cause serious safety accidents. 

Connection cable

: the connection cable between the controller and the battery is as short as possible, 

which can effectively reduce the cable loss and reduce the voltage difference.

Recommended cable specifications:    

length < 4m: 8mm    ,

 

length > 4m: 10mm

               

2

1. 

The controller has two solar panel input ports, each with a maximum charging current of 30A 

      It can be connected arbitrarily, and the controller can work normally if only any one of the solar panels is connected. 

2.   For details of the maximum open-circuit voltage and power of the solar panel, see the parameter table below. 

3.   The battery must be connected before connecting the solar panel. 

4.   The size of solar panel cable is more than that of 4mm.

Load connection

1.The controller does not have a load output port directly, but it has a dry contact port, 
    user can control the external relay or the controller signal as the external load 
    through the dry node. 
2.The output voltage of the dry contact port is the voltage of the battery and the output 
    current is 2A. 
3. Verify that the working voltage of the externally connected relay or load control signal 
    is consistent with the output voltage of the dry contact port. 
3. There are five modes of dry contact signal output: manual mode, pure light control mode, 
    light control on + time control off. Single-period real-time time control, dual-period 
    real-time time control

1. Multiple controllers are connected in parallel to share a battery pack. But each controller must be connected to a 

    separate solar panel matrix. 

2.In the expansion system, it is recommended that the specifications of each controller and the solar panel matrix be the same, 

  which is conducive to charge equalization.

F

U

S

E

FUSE

Pv1

P V

2

Pv1

P V

2

fuse

+

-

+

- +

- + -

PV

1

PV

2

fuse

f

u

s

e

Summary of Contents for MPPT15060

Page 1: ...sure that the battery works in the best state and greatly prolong the service life of the battery 8 It has full automatic control such as overcharge overdischarge overload protection anti reverse protection and so on The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages It shall be used with vented or sealed VRLA lead acid batteries only Safety Recommend...

Page 2: ...irtight battery where gas may accumulate the place Warning high pressure is dangerous PV arrays may generate high open circuit voltages Disconnect circuit breakers or safety before wiring and be careful during wiring Note when installing the controller make sure that enough air flows through the heat sink of the controller and there is at least 150mm space above and below the controller to ensure ...

Page 3: ...afety accidents Connection cable the connection cable between the controller and the battery is as short as possible which can effectively reduce the cable loss and reduce the voltage difference Recommended cable specifications length 4m 8mm length 4m 10mm2 1 The controller has two solar panel input ports each with a maximum charging current of 30A It can be connected arbitrarily and the controlle...

Page 4: ...ntal stripes rolling up dynamically Load ON Load OFF Press K1 or K2 to cycle forward or backward to browse the current working parameters or set working status Battery voltage PV1 voltage PV2 voltage Charge current PV power Ambient temperature Charging capacity AH Charging capacity WH Parameter setting browsing In the battery voltage display interface press the K3 button for 5 seconds to enter the...

Page 5: ...erface Browse and press K1 or K2 to cycle to the parameter interface you want to set Short press K3 button SET display SET font flashes to indicate that you can start to change the current parameter press K1 or K2 to modify the parameter value and then press K3 button set button save the current settings and the word SET will stop flashing and so on you can set other parameters Press K4 key to dir...

Page 6: ...ashes press K1 or K2 key to change the number of minutes in a cycle 0 59 5 Press the K3 key again the SET and M icons stop flashing the load time is set and save the settings Dual period real time control mode Turn the page of the load working mode to the dual period real time control interface mode 5 1 Press the K3 key the H icon flashes the ON1 icon is on press K1 or K2 key to modify the cycle n...

Page 7: ... the battery voltage here otherwise The controller will report an error and the controller will not work Battery voltage Automatic identification Set night detection voltage The night detection voltage is the voltage of the solar panel when the load is turned on and output it needs to be used when the load working mode is set to pure light control or light control time control Charging capacity se...

Page 8: ...ror code is displayed and the buzzer alarms synchronously and the alarm continues until the error is corrected Press K4 to exit the wrong generation interface return to the main interface and turn off the buzzer Start timing If the error persists after 10s the alarm will continue Ring every 0 5 seconds for one minute rings once in 0 5 seconds and the full battery icon flashes rings once in 0 5 sec...

Page 9: ... Float charge 13 5V 13 8V 13 5V 13 14V Boost charge recovery 13 2V Low voltage recovery load output 12 5V 11 5V 12 5V Low voltage protection shut off load 11V 10 5V 11 5V Equalization charge time 120min Temperature compensation 3mv 2V Load work mode manual light control time contorl Real time timing control Night detection voltage 6V Dry contact terminal output voltage Same as battery voltage curr...

Reviews: