OLYS MPPT15060 User Manual Download Page 6

load

 

work

 

mode

1:manual mode

K

3

K

1

K

2

3

K

1

K

2

K

1

K

2

K

1

K

2

Single period real time control

: 

Set load working mode

There are 5 load working modes: 

1: manual mode:  press the K4 button  to turn the load output on or off. 

2: pure light control mode:  the voltage of the solar panel is detected automatically, the load is turned on at dark and the load is 

    turned off at dawn. 

3: light c time control mode: the load starts the light control, and the load closing time is set by the user. 

4: single  real time control: Users can set real-time time to enable and close the load. 

5: double-time real time control : , users can set two real-time periods to output and turn off the load of the controller, such as 

    8: 00 a.m. to 10:00 and 2: 00 p.m. to 4: 00 p.m.

Set operation instructions: 

Manual mode and pure light control

 mode do not need to set the time, and the other three modes need to set the working time. 

The operation are as follows: 

Light c time contro

l: Turn the page to  the load working mode to light c time control interface (mode 3), press K3 key, 

"SET" and "H" font flash, press K1 or K2 key to set the number of hours, the setting is finished. 

Then press K3 key, "SET" and "M" font flash, press K1 or K2 key to set the number of minutes, after setting, press K3 key again, 

“SET" and "M" stop flashing, save finished

Turn the page of the load working mode to the single real time control interface (mode 4)

1.

Press K3 key, "H" flashing, "ON" on, short press K1 or K2 key to cycle change hours: 0- - 23. 

2. Press K3 again, "H" stops flashing, "M" flashes, press K1 or K2 to change the number of minutes: 0--59. 

3. Press the K3 key again, when the load time is set, the “ON” icon is off; the “OFF” icon is on, the “M” icon stops flashing, the 

   “H” icon is  flashing, and press K1 or K2 key to modify the cycle number of hours: 0--23. 

4. Press the K3 key again, the “H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes in a 

   cycle: 0--59.  

5. Press the K3 key again, the SET and M icons stop flashing, the load time is set, and save the settings.

Dual-period real-time control mode

Turn the page of the load working mode to the dual-period  real time control interface (mode 5)

1. 

Press the K3 key, the “H” icon flashes, the “ON1” icon is on, press K1 or K2 key to modify the cycle number of hours: 0--23. 

2.

 

Press the K3 key again, the “H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes 

    in a cycle: 0--59. 

3. Press the K3 key again, when the load time 1 is set, the” ON1” icon is off, the “OFF1” icon is on, the “M” icon stops flashing, 

   the” H” icon flashes, and press K1 or K2 key to modify the cycle number of hours: 0--r23. 

4. Press the K3 key again, the” H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes

     in a cycle: 0--59. 

5. Press the K3 key again, the “M” icon stops flashing, the load time 1 is set up, the “H” icon flashes, the “ON2” icon is om, press 

    the K1 or K2 key to modify the cycle number of hours: 0--23. 

6. Press the K3 key again, the “H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes

    in a cycle: 0--59. 

7. Press the K3 key again, when the load time 2 is set, the “ON2” icon is off, the “OFF2” icon ison, the “M” icon stops flashing, the 

    “H” icon flashes, press K1 or K2 key to modify the cycle number of hours: 0--23. 

8. Press the K3  key again, the “H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes

     in a cycle: 0-- 59. 

9. Press the K3 key again, the “SET” and” M” icons will stop flashing, and the load time 2 will be set up. Save the settings.

2:pure light mode

Light c 
time control

4: Single period 
real time control

5: Dual-period 
real-time control
mode

 

ON

OFF

Load OFF

K

4

K

4

短按

Load ON

Manually turn on and off the load

When the load mode is manual mode 1 and is not in the "alarm function" period, short press the K4 button to turn on the load, 
while in ot her modes, the K4 button is invalid

Summary of Contents for MPPT15060

Page 1: ...sure that the battery works in the best state and greatly prolong the service life of the battery 8 It has full automatic control such as overcharge overdischarge overload protection anti reverse protection and so on The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages It shall be used with vented or sealed VRLA lead acid batteries only Safety Recommend...

Page 2: ...irtight battery where gas may accumulate the place Warning high pressure is dangerous PV arrays may generate high open circuit voltages Disconnect circuit breakers or safety before wiring and be careful during wiring Note when installing the controller make sure that enough air flows through the heat sink of the controller and there is at least 150mm space above and below the controller to ensure ...

Page 3: ...afety accidents Connection cable the connection cable between the controller and the battery is as short as possible which can effectively reduce the cable loss and reduce the voltage difference Recommended cable specifications length 4m 8mm length 4m 10mm2 1 The controller has two solar panel input ports each with a maximum charging current of 30A It can be connected arbitrarily and the controlle...

Page 4: ...ntal stripes rolling up dynamically Load ON Load OFF Press K1 or K2 to cycle forward or backward to browse the current working parameters or set working status Battery voltage PV1 voltage PV2 voltage Charge current PV power Ambient temperature Charging capacity AH Charging capacity WH Parameter setting browsing In the battery voltage display interface press the K3 button for 5 seconds to enter the...

Page 5: ...erface Browse and press K1 or K2 to cycle to the parameter interface you want to set Short press K3 button SET display SET font flashes to indicate that you can start to change the current parameter press K1 or K2 to modify the parameter value and then press K3 button set button save the current settings and the word SET will stop flashing and so on you can set other parameters Press K4 key to dir...

Page 6: ...ashes press K1 or K2 key to change the number of minutes in a cycle 0 59 5 Press the K3 key again the SET and M icons stop flashing the load time is set and save the settings Dual period real time control mode Turn the page of the load working mode to the dual period real time control interface mode 5 1 Press the K3 key the H icon flashes the ON1 icon is on press K1 or K2 key to modify the cycle n...

Page 7: ... the battery voltage here otherwise The controller will report an error and the controller will not work Battery voltage Automatic identification Set night detection voltage The night detection voltage is the voltage of the solar panel when the load is turned on and output it needs to be used when the load working mode is set to pure light control or light control time control Charging capacity se...

Page 8: ...ror code is displayed and the buzzer alarms synchronously and the alarm continues until the error is corrected Press K4 to exit the wrong generation interface return to the main interface and turn off the buzzer Start timing If the error persists after 10s the alarm will continue Ring every 0 5 seconds for one minute rings once in 0 5 seconds and the full battery icon flashes rings once in 0 5 sec...

Page 9: ... Float charge 13 5V 13 8V 13 5V 13 14V Boost charge recovery 13 2V Low voltage recovery load output 12 5V 11 5V 12 5V Low voltage protection shut off load 11V 10 5V 11 5V Equalization charge time 120min Temperature compensation 3mv 2V Load work mode manual light control time contorl Real time timing control Night detection voltage 6V Dry contact terminal output voltage Same as battery voltage curr...