OLYS MPPT15060 User Manual Download Page 1

  MPPT15060

MPPT

3

3

0

232

50

205

87.5

Solar Charge Controller
USER MANUAL

Thank you very much for buying our product ,Please read

thoroughly before using the prouuct

Description

 

of

 

Functions

1. 

Suitable for charging 12V/24V/36V/48V lead-acid batteries, including GEL, Sealed, Flooded battery

2. Mainly suitable for off-grid solar power generation systems, such as: home solar power generation system, solar RV power generation, 

    boat, unattended base stations, outposts and so on. 

3. MPPT charging technology, three-stage charging mode, constant current charge-constant voltage charge-floating charge, 

   effectively improve the battery charging efficiency.  It is more portable than ordinary PWM charging.

4. Suitable for high voltage input, PV voltage up to 150 V (At the lowest temperature -25

). 

5.  input two Channel solar panels at the same time. 

6. This product adopts intelligent single-chip microcomputer design, and all workflows are controlled by software, which can achieve 

     high precision and high reliability. 

7. The charging mode of high-efficiency MPPT is adopted to ensure that the battery works in the best state and greatly prolong the 

    service life of the battery. 

8. It has full automatic control such as overcharge, overdischarge, overload protection, anti-reverse protection and so on

The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages, It shall be used 

with vented or sealed (VRLA) lead  acid batteries only.

Safety Recommendations:

   1.Batteries store a large amount of energy. Never short circuit a  battery whatever.

   2.Batteries can produce flammable gases. Avoid making sparks, using fire or any naked flame. Make sure that the battery

   room is ventilated.

   3.Avoid touching or short circuiting wires and  terminals. Be aware that the voltages on specific terminals and  wires can

   be up to  double of battery voltage. Use isolated tools. Stand on dry ground and keep your hands dry. 

  

Installation

Attentions

Please  installed in the room, avoiding direct-clearance,

do not install in the wet environment, when use it outdoor, 

please install controller and batteries in the same place, 

and the batteries installed in the same place, the controller

can  measuring the battery temperature, charge 

voltage regulation.

Attention:

1. Screws  specifications M4

2. Make sure heat-location were not l  blocke

Summary of Contents for MPPT15060

Page 1: ...sure that the battery works in the best state and greatly prolong the service life of the battery 8 It has full automatic control such as overcharge overdischarge overload protection anti reverse protection and so on The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages It shall be used with vented or sealed VRLA lead acid batteries only Safety Recommend...

Page 2: ...irtight battery where gas may accumulate the place Warning high pressure is dangerous PV arrays may generate high open circuit voltages Disconnect circuit breakers or safety before wiring and be careful during wiring Note when installing the controller make sure that enough air flows through the heat sink of the controller and there is at least 150mm space above and below the controller to ensure ...

Page 3: ...afety accidents Connection cable the connection cable between the controller and the battery is as short as possible which can effectively reduce the cable loss and reduce the voltage difference Recommended cable specifications length 4m 8mm length 4m 10mm2 1 The controller has two solar panel input ports each with a maximum charging current of 30A It can be connected arbitrarily and the controlle...

Page 4: ...ntal stripes rolling up dynamically Load ON Load OFF Press K1 or K2 to cycle forward or backward to browse the current working parameters or set working status Battery voltage PV1 voltage PV2 voltage Charge current PV power Ambient temperature Charging capacity AH Charging capacity WH Parameter setting browsing In the battery voltage display interface press the K3 button for 5 seconds to enter the...

Page 5: ...erface Browse and press K1 or K2 to cycle to the parameter interface you want to set Short press K3 button SET display SET font flashes to indicate that you can start to change the current parameter press K1 or K2 to modify the parameter value and then press K3 button set button save the current settings and the word SET will stop flashing and so on you can set other parameters Press K4 key to dir...

Page 6: ...ashes press K1 or K2 key to change the number of minutes in a cycle 0 59 5 Press the K3 key again the SET and M icons stop flashing the load time is set and save the settings Dual period real time control mode Turn the page of the load working mode to the dual period real time control interface mode 5 1 Press the K3 key the H icon flashes the ON1 icon is on press K1 or K2 key to modify the cycle n...

Page 7: ... the battery voltage here otherwise The controller will report an error and the controller will not work Battery voltage Automatic identification Set night detection voltage The night detection voltage is the voltage of the solar panel when the load is turned on and output it needs to be used when the load working mode is set to pure light control or light control time control Charging capacity se...

Page 8: ...ror code is displayed and the buzzer alarms synchronously and the alarm continues until the error is corrected Press K4 to exit the wrong generation interface return to the main interface and turn off the buzzer Start timing If the error persists after 10s the alarm will continue Ring every 0 5 seconds for one minute rings once in 0 5 seconds and the full battery icon flashes rings once in 0 5 sec...

Page 9: ... Float charge 13 5V 13 8V 13 5V 13 14V Boost charge recovery 13 2V Low voltage recovery load output 12 5V 11 5V 12 5V Low voltage protection shut off load 11V 10 5V 11 5V Equalization charge time 120min Temperature compensation 3mv 2V Load work mode manual light control time contorl Real time timing control Night detection voltage 6V Dry contact terminal output voltage Same as battery voltage curr...