![Olympia HT 430-23A Instruction Manual Download Page 4](http://html1.mh-extra.com/html/olympia/ht-430-23a/ht-430-23a_instruction-manual_3905689004.webp)
Model
Supply voltage
Max. Current
consumption
100 mA
Batteries
2x AA batteries, 1.5V
Display
LCD
Dimensions
60 x 58 x 94 mm
Weight (incl. adapter
and batteries)
155 g
Connection
M30 x 1.5 mm
Ambient temperature -10 to 50°C
Disposal
Find out about the
possibilities of taking back
old devices and used
batteries free of charge
from your dealer.
The adjacent symbol means
that, due to legal regulations,
old electrical and electronic
devices must be disposed of
separately from household
waste. Dispose of your device at
the collection point of your local
waste disposal authority.
Defective or used batteries must
be recycled in accordance with
Directive 2006/66/EC and its
amendments. Return batteries
and/or the device via the
collection facilities provided.
Dispose of packaging materials
according to local regulations.
Pay attention to the marking of
the packaging material when
separating waste, these are
marked with abbreviations (b)
and numbers (a) with the
following meaning: 1-7: plastics
/ 20-22: paper and cardboard /
80-98: Composites.
Questions and service
Dear Customer,
we are pleased that you have chosen this
device.
If you have any questions or problems, our
service hotline is at your disposal under the
telephone number
+49 (0)180 5 007514 (costs from the
dt. Landline at time of printing: 14ct/min,
mobile max. 42ct/min.) available.
You can also find more information in
our returns portal (RMA) in the section
Support on our website
www.go-europe.com.
A return is made by enclosing
the proof of purchase and ideally in the
original packaging
an:
WSG Wilhelmshaven Service
Company ltd.
Krabbenweg 14
26388 Wilhelmshaven
Germany
Manufacturer
GO Europe GmbH
Zum Kraftwerk 1
45527 Hattingen
Germany
Declaration of conformity
The full text of the EU
Declaration of Conformity can
be found at the following
Internet address or by
scanning the QR code:
http://productip.com/?f=1eb3
f5
Help
Problem
Cause
Solution
Batteries largely depleted.
Change batteries.
Radiator does not get warm.
Boiler water temperature, O.K.? Valve does not open after summer heating
break - calcified?
Radiator does not get cold.
Valve does not close completely. Possibly
the closing point of your valve seal is displaced.
Adapt again (see "Adaptation"); move the valve tappet by
hand several times - adaptation may not be possible because
your valve may be calcified, or the seal no longer fulfills its
function.
Pressure piece falls out. (This can also
cause an F1 error!)
By means of an endless thread, the threaded hole on the lower
side may fall out if the regulator has not been applied to the valve.
Insert the pressure piece. Adapt the device by pressing the
OK key or by removing and reinserting the batteries. The
endless thread now turns and tightens the pressure piece
again. Attach to the radiator and adapt again.
F1-F4
Pressing any key after the error has been corrected clears the error indication in the display and the adaptation restarts. The device can then
be used as usual.
F1
The valve actuator is sluggish.
Check if the radiator valve is blocked.
F2
The adjustment range of the radiator valve is too large.
Check the correct fixing of the radiator valve.
F3
The adjustment range of the radiator valve is too small.
Check if the radiator valve is blocked
or the valve
resistance is too high.
F4
The valve drive has not been installed correctly or the valve travel has not been
detected correctly.
Repeat the adaptation run.
The device is in the delivery state.
with OK (10 b).
3.
The display (3) shows COnF and confirm
(10 b).
Select menu item rES
and confirm with OK
2.
the menu.
Press and hold the Menu key (10 a) to enter
1.
made will be deleted.
settings, all personal settings that you have
Attention
! If you reset the device to factory
Reset to factory setting
Select setting or and confirm with OK (10 b).
3.
shows the automatic changeover is activated.
changeover is deactivated. If the display
If the display shows (3) OFF, automatic
OK (10 b).
Select menu item dSt and confirm with
2.
the menu.
Press and hold the Menu key (10 a) to enter
1.
winter time can be activated or deactivated.
The automatic changeover of summer and
Summer and winter time changeover
deactivated.
The LOC display goes out and the child lock is
simultaneously.
Press Time (10 c) + Menu (10 a) keys
2.
want to use
the device again.
Deactivate the parental control when you
activated.
The display (3) shows LOC, and the child lock is
(10 a) keys simultaneously for 2 seconds.
Press and hold the Time (10 c) + Menu
1.
can lock the HT 430-23A.
To protect
against unauthorized operation, you
Child lock
changes for the purpose of improvement.
We
reserve the right to make technical
Technical data
run 1x a week (Friday morning).
the device performs a limescale protection
To prevent calcification of the radiator valves,
Limescale protection function
the display (3) shows OFF.
Turn the setting wheel (5) to the right until
2.
Switch to manual
mode
1.
function remains active.
During a heating pause, the frost protection
saving times.
a heating pause or program new heating and
Switch back to automatic mode at the end of
summer months, for
example.
heating
pause if you do
not want to heat in the
prevents the radiators
from freezing. Set a
temperature rises
above 5°C again. This
430-23A opens the valve until the
If the temperature drops to 0°C, the HT
Frost protection function/ heating pause
HT 430-23A 3
V
you
may damage the device.
the HT 430-23A. Avoid chemical solvents,
Only use a dry to slightly damp cloth to clean
Cleaning
times
by hand/tool.
430-23A. Move the valve tappet back and forth several
Correct the boiler water temperature. Disassemble the HT
confirm with OK (10b).
function with the setting wheel (5) and
4. Set the temperature for the holiday
(10b).
the setting wheel (5) and confirm with OK
hour, minute) of the holiday function with
3. Set the starting time (year, month, day,
confirm with OK (10b).
hours with the setting wheel (5) and
2. Set the duration of the holiday function in
shows the holiday function (7).
for about one second until the display (3)
1. Press and release the Menu button (10a)
constant for a set period.
The vacation
function keeps the temperature
Vacation function
window open detection.
Press the OK key (10 b) to interrupt the
and confirm with OK (10 b).
Set the time until the radiator valve opens
4.
with OK (10 b).
Set the desired temperature and confirm
3.
b).
Select menu item and confirm with OK (10
2.
the menu.
Press and hold the Menu key (10 a) to enter
1.
in the display.
energy. The window open symbol (8c)appears
automatically closes the heating valve to save
temperature to drop sharply, the HT
430-23A
If
you open a window and this causes the
Window function
does not change due to the adjustment.
The temperature indication in the display (3)
OK (10 b).
(from
-5.5 °C to +5.5 °C) and confirm with
Set the temperature adjustment
3.
OK (10 b). 0.0° flashes in the display (3).
Select menu item
t0F
and confirm with
2.
the menu.
Press and hold the Menu key (10 a) to enter
1.
adjustment.
temperature, you can perform a temperature
If the felt temperature differs from the set
Offset