background image

Page

 4 

from

 7

92303

7

00

8

_09_00

1

The light source contained in this luminaire shall only be replaced by the manufacturer, or his 

agent, or a similar qualified person.

NOTE! The light source is non-user replaceable.

(*)

Non  Maintained  operation:  The  luminaire 

lights  its  illumination  source,

 

only  in  power 

supply’s failure. 

 

Maintained operation: The luminaire lights its 
illumination source, when it is powered by the 
mains power supply or not

NOTE: 

LED= Light Emitting Diode

LABELING EXPLANATION:
X: 

Self contained 

  

0: 

Non Maintained (*)

A: 

Including test device 

 

B: 

Including remote rest mode

C: 

Including inhibiting mode

*90 : 

1.5 hour duration

180: 

3 hours duration

11  Connect the address cables, in the terminal block with the indicating polarity (Fig.2).
12  Address the luminaire by using the dip-switches with the appropriate combinations as you
      can see in pages 

5

 and 

6

 (Fig.3).

  

Address module connections

GR-6500 Loop

L

L

+L  -L

L

L

Fig.2

Fig.3

1

2

1

1

LED MODULE CHARACTERISTICS

Olympia Electronics S.A

.

6

5

 °C  max. across the board

Cable connection between main pcb and led module

17.

1

-

18

.

6

V DC

1

1

W

1005183

Manufacturer

Manufacturer
Voltage Range

Connections

Nominal Power

Temperature (tc)

GRL-37/90/ADR

GRL-37/180/ADR

Summary of Contents for GRL-37/90/ADR

Page 1: ...this state during the power supply failure and when the battery has been fully discharged In this state the luminaire draws the least power from the battery in order to prevent deep discharge MANUALTE...

Page 2: ...go OFF before the end of the test then the unit is restored to its normal operation but the LAMP FAULT BATT FAULT indicator is lit to show that there is a problem with the battery and that the battery...

Page 3: ...al autonomy INSTALLATION PROCEDURE For wall mounting only Page 3 from 7 923037008_09_001 INDICATION LED STATUS with the mains power supply connected Battery replacement It can be done only by a compet...

Page 4: ...tained 0 Non Maintained A Including test device B Including remote rest mode C Including inhibiting mode 90 1 5 hour duration 180 3 hours duration 11 Connect the address cables in the terminal block w...

Page 5: ...7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON O...

Page 6: ...8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON...

Page 7: ...vided or has any repairs or re setting done by a third party unless Olympia Electronics has fully agreed to them in writing Products that have been damaged can be returned to the premises of our compa...

Reviews: