background image

Page

 3

 from

 

11

940818000

_09_00

4

the night program, press the           key for 
more than 

 3", 

the symbol     is replaced by 

the symbol     .

    

3. Boiler ACTIVATION   

(available only on 

the BS-819/KIT).

This capability can be executed by pressing 
briefly the                 key, the backlight will be 
activated for 2" and the           symbol will be 
shown on the top left corner of the screen. 
The built-in relay will send the command to 
the burner.

 

The command will be active for 

as long as it has been preselected via the 
MENU setting with the indication       

(

Boiler 

time), or until the       key is pressed again.

 

   

 

   

If the preselected Boiler value is 00 then 

the deactivation can be done only with the 
key.

 

The  Boiler  command  is  independent 

from the other functions of the device and 
can  be  given  even  if  the  thermostat  is 
deactivated

  (

OFF  state).  The  factory 

default Boiler time is 

 00 

minutes

.  

4. AREA PRESENCE SELECTION

 

( The 

thermostat is in the ON state).

In normal operation, the symbol      shows 
the presence of people in the area and all 
the  programs,  which  ever  they  are,  are 
executed normally. In limited absence from 
the  area(from  a  few  hours  to  a  few  days) 
there  is  the  capability  to  execute  the 
absence program.

 

If the      

 

key is pressed for 3", the backlight 

will be activated for 2" and the       symbol           
will  be  changed  to    .This  command 
superimposes  every  other  program.  The 
selected  temperature  is  shown  on  the 
screen if any of the                             keys is 
pressed

 

and can’t be changed. The value 

can be changed only with the        selection      

(

Absent  time)  of  the

 

MENU

The  factory 

default setting of this temperature is 

 16.0 

º

C

 

and can be altered from

 6.0 

to

 30.0 º

C

To  deactivate  the  absence  mode,  the               
key          must  be  pressed  for  3",  then  the 
thermostat  will  continue  the  execution  of 
the  program  that  was  running  before 
absence mode was selected.

5. 

KEYPAD LOCK

 

(

in any operation state

).

If  the  keys        and      are  pressed 
simultaneously for 3"

(

first the           key and 

then  the       

)  ,

the  screen  will  show  the 

message      and the keypad is locked.

 

Page

 3

 from

 

11

GENERAL

When  the  plastic  battery  separator  is 
remove the unit is automatically  activated 
and  shows  all  the  screen  indicators  for 

1",

then the firmware version is shown and 

finally  the  screen  enters  final  operation 
status.

   

In the center of the screen we can 

see the current temperature

The clock has 

the  hour

  00

:

00

,  the  date  is  1  January 

(Friday) 2016 and the thermostat is inactive

 

(

OFF state). In this state the only available 

s e l e c t i o n s   a r e   B o i l e r  
activation/deactivation  (only  for

 

BS-

819

/ΚΙΤ

) and entry to the settings menu

If 

the 

       

key  is  pressed  momentarily 

the 

screen illumination will be activated for 

 2" 

and the symbols       ,       and

 

ΜΑΝ

 

 

will be 

shown which are the factory defaults.

1. 

ENTERING THE MENU

 

(

the thermostat 

in the OFF state

)

.

To  enter  the  menu  settings  press  the           
button         for more than 

3". 

The screen will be illuminated and will stay 
illuminated  during  all  the  duration  of  the 
settings Please note that only settings that 

are  blinking  can  be  changed To  navigate 

through  the  menu  items  use  the                                                                                   
keys       and        . To change the value of a 
menu item use the keys                 . Press 
the       key to accept the change or press 
the       key to go to the previous state. If no 
key  is  pressed  for  2  minutes  then  the 
thermostat  returns  to  normal  operation 
while saving the changed settings

.

2 .  

S E L E C T I N G

 

D AY   O R   N I G H T  

OPERATION MODE

  

       

(

the  thermostat  is  in  the  ON  state  and  in 

manual operation

).

If the             key is pressed for more than 3" 
then the    indication is deactivated and we 
can  see  the    .  This  means  that  night 
operation  mode  has  been  selected.  This 
selection replaces temporarily the manually 
selected  temperature  for  as  long  as  the 
night  program  is  active. If  one  of  the                     

 

keys          

is pressed then the set night 

    

program   temperature is shown.   

(

this can 

be changed from the setting          

(

night) of 

the 

ΜΕΝ

U)

The  factory  default  night 

temperature is set to 

18.0º

C. To deactivate 

MENU

ENTER

ESC

MENU

ENTER

ESC

ESC

MENU

ENTER

MENU

ENTER

Summary of Contents for BS-818/KIT

Page 1: ... BS 819 R Thank you for your trust in our products Olympia Electronics European manufacturer 8 7 6 5 4 3 2 1 CONTROL AND INDICATOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat inactive Battery state indicator Ascending or descending temperature indicator When the selection is less than the actual temperature...

Page 2: ...creen messages page 6 Daily programming example page 7 Weekly programming example page 8 Wireless communication settings page 8 communication errors page 9 Hour and message display Temperature and message display Temperature units display Active burner output display Selecting on not the area presence program Escape from a selection Activate Deactivate boiler valid only for the BS 819 T Go to the ...

Page 3: ...imultaneously for 3 first the key and then the the screen will show the message and the keypad is locked Page 3 from 11 GENERAL When the plastic battery separator is remove the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen we can see the current temperatur...

Page 4: ...nce the end time is the start time of the next program For example if we require a temperature of 23 0 ºC from 14 00 to18 00 in program 1 we will set the start time 14 00 at 23 0 ºC and the start time of the second program 18 00 with the required temperature The 24 hour time base starts at 00 00 and ends at 23 59 The start time of the next program must also be bigger than the start time of the pre...

Page 5: ... With this setting we can turn off the screen illumination in order to conserve battery energy If ΟΝ is selected then the screen illumination will be activated every time a key is pressed If is selected then the screen illumination will be deactivated The factory default is D LED BURNER OUTPUT INDICATOR This setting can deactivate the burner output indicator in order to conserve battery energy If ...

Page 6: ...perate The battery life time has been design to be approximately 2 years Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality 12 ANTI ICE PROTECTION If the room temperature in which the thermostat is installed falls below 5 C the unit activates the burner output irrelevant of the ON or OFF st...

Page 7: ... blinking 4 Press the key and the starts to blink With the keys and we select the operation mode Day daily program 5 Press the key and we return to the previous screen with the blinking 6 Press the key 8 times and the screen shows with the blinking Now we are in the daily programming sub menu that has a 10 program capability 7 Press the key and the screen shows with the blinking this shows that we...

Page 8: ...the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTING This procedure is required for every new installation in order to establish the communication and to verify the quality of the signal After installing the peripheral received BS 818 R or BS 819 R t...

Page 9: ...e interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands that will be giv...

Page 10: ...a maximum torque of 0 5 Nm To activate the device remove the battery separation tape Fig 3 Install the front cover with slight pressure and the device is ready to operate To install the BS 818 R or BS 819 R remove the 4 screws of the front cover Fig 4 and remove the cover Mark and drill the mounting holes according to page 10 Mount the device using the supplied mounting accessories Holes A and B a...

Page 11: ...r not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr TECHNICAL CHARACTERISTICS BATTERIES 2 Alkaline ΑΑ BS 818 T BS 819 T BS 819 R BS 818 R MODEL 220 240V AC ...

Reviews: