background image

Olympia Electronics guarantees the quality, condition and operation of the goods. The 
period of warranty is specified in the official catalogue of Olympia Electronics and also in 
the technical leaflet, which accompanies each product. This warranty ceases to exist if the 
buyer does not follow the technical instructions included in official documents given by 
Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-
setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. 

Products that have been damaged can be returned to the premises of our company for 
repair or replacement, as long as the warranty period is valid.

Olympia Electronics reserves the right to repair or to replace the returned goods and to 
or not charge the buyer depending on the reason of defection. Olympia Electronics 
reserves the right to charge or not the buyer the transportation cost.

HEAD OFFICE

72

nd

 

km

O

.

N

.

R

Thessaloniki-Katerini

P.C. 60300 P.O. Box 06 Εginio Pierias Greece

www.olympia-electronics.gr
[email protected]

TECHNICAL CHARACTERISTICS

BATTERIES

2

  

Alkaline

 ΑΑ

BS-818/T - BS-819/T

BS-819/R

BS-818/R

MODEL

220 - 240V AC / 50-60Hz

OPERATION TEMPERATURE RANGE

RELATIVE HUMIDITY

EXTERNAL DIMENSIONS

TYPICAL WEIGHT

GUARANTEE

MEASURING RANGE

OPEN RELAY CONTACT

DEGREES OF COVER PROTECTION

 

PRODUCED IN ACCORDANCE WITH

5Α - 250

V AC1

o

0.0 

to

 99.9 

C

EN 61000-6-1, EN 61000-6-3, EN 60730-1, EN 60730-2-9

o

5 to 35  C

10 -

 90% RH 

2 years

121,5 x 27,3 x 81,3 mm

IP 20

 2x

5Α - 250

V AC1

175 gr. (with batteries)

225

 

gr

.

230 gr

.

o

-10 to 50  C

IP 65

10 -

 9

5

% RH 

158 

79,2

 x 

45 

mm

.

 

-

CONSUMPTION

1,8VA

1,9VA

Page

 

11 from

 

11

940818000

_09_00

4

WARRANTY

WARRANTY

-

COMMUNICATION FREQUENCY

869,75

MHz

TEMPERATURE SELECTION RANGE

o

6.0 

to

 30.0 

C

-

-

Summary of Contents for BS-818/KIT

Page 1: ... BS 819 R Thank you for your trust in our products Olympia Electronics European manufacturer 8 7 6 5 4 3 2 1 CONTROL AND INDICATOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat inactive Battery state indicator Ascending or descending temperature indicator When the selection is less than the actual temperature...

Page 2: ...creen messages page 6 Daily programming example page 7 Weekly programming example page 8 Wireless communication settings page 8 communication errors page 9 Hour and message display Temperature and message display Temperature units display Active burner output display Selecting on not the area presence program Escape from a selection Activate Deactivate boiler valid only for the BS 819 T Go to the ...

Page 3: ...imultaneously for 3 first the key and then the the screen will show the message and the keypad is locked Page 3 from 11 GENERAL When the plastic battery separator is remove the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen we can see the current temperatur...

Page 4: ...nce the end time is the start time of the next program For example if we require a temperature of 23 0 ºC from 14 00 to18 00 in program 1 we will set the start time 14 00 at 23 0 ºC and the start time of the second program 18 00 with the required temperature The 24 hour time base starts at 00 00 and ends at 23 59 The start time of the next program must also be bigger than the start time of the pre...

Page 5: ... With this setting we can turn off the screen illumination in order to conserve battery energy If ΟΝ is selected then the screen illumination will be activated every time a key is pressed If is selected then the screen illumination will be deactivated The factory default is D LED BURNER OUTPUT INDICATOR This setting can deactivate the burner output indicator in order to conserve battery energy If ...

Page 6: ...perate The battery life time has been design to be approximately 2 years Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality 12 ANTI ICE PROTECTION If the room temperature in which the thermostat is installed falls below 5 C the unit activates the burner output irrelevant of the ON or OFF st...

Page 7: ... blinking 4 Press the key and the starts to blink With the keys and we select the operation mode Day daily program 5 Press the key and we return to the previous screen with the blinking 6 Press the key 8 times and the screen shows with the blinking Now we are in the daily programming sub menu that has a 10 program capability 7 Press the key and the screen shows with the blinking this shows that we...

Page 8: ...the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTING This procedure is required for every new installation in order to establish the communication and to verify the quality of the signal After installing the peripheral received BS 818 R or BS 819 R t...

Page 9: ...e interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands that will be giv...

Page 10: ...a maximum torque of 0 5 Nm To activate the device remove the battery separation tape Fig 3 Install the front cover with slight pressure and the device is ready to operate To install the BS 818 R or BS 819 R remove the 4 screws of the front cover Fig 4 and remove the cover Mark and drill the mounting holes according to page 10 Mount the device using the supplied mounting accessories Holes A and B a...

Page 11: ...r not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr TECHNICAL CHARACTERISTICS BATTERIES 2 Alkaline ΑΑ BS 818 T BS 819 T BS 819 R BS 818 R MODEL 220 240V AC ...

Reviews: