31.
Correctly orientate
3G
- Side Roof Panel
, with shingles overhanging
plywood on the side of the shed and flush with plywood toward the center of
the shed. Place on rafters with front of plywood just about flush with rafter
ends but just slightly recessed. Doing so allows front facia to sit better.
32.
For correct Roof Panel position, align panel so plywood sits evenly on Center Rafters. Next, position
3H
- Center Roof Panel
onto center rafters.
Shingles overhang
plywood on outside.
Front of plywood
1/8” recessed
with rafter end.
Plywood flush
with shingles
on inside.
Parts (Steps 31 - 34)
3G
- Left/Right Roof Panels
(51” x 56”)
x 2
3H
- Center Roof Panel
(45 1/2” x 56”)
x 1
Roof Panel
centered on
rafter.
33.
Align plywood of center roof panel so it is tight against the plywood of the side roof panel. Spacing
should be even front and back.
Toll Free 1-888-658-1658 www.outdoorlivingtoday.com [email protected]