background image

PAGE 13

3.8 -  Regulation of Combustion Air

On the Combustion lever, shown in Fig. A, each marker is an individual setting, as shown below:

• II ..... Ignition position, max. heat output
• I....... Nominal heat output with billet wood 
• I....... Nominal heat output with wood briquettes
• 0 ..... Obtain glow

As the secondary air also contributes to the cleanliness of the glass pane, the operating lever should be set 
on “I” minimum. This also applies in the event of low-load operation. When not in use the lever should be 
set on“0”, to reduce the cooling down of the room.

3.0 OPERATING INSTRUCTIONS

3.9 - Using the Wood Storage Compartment

The wood storage compartment below the combustion chamber 
is  fitted with a magnetic pressure closure. It can be opened by 
lightly pressing on the button (Olsberg logo). Likewise it can be 
closed by lightly pressing.

4.0 - Measuring Negative Pressure

Above  the  combustion  chamber  opening,  behind  the  upper 
door, there is a measuring duct on which the negative pressure 
in  the  combustion  chamber  can  be  measured  with  the  door 
closed during heating operation.

17

Combustion air slide valve

Operating lever for combustion air supply

 

Operating lever on „0“: 

 

all slide valves closed

 

Operating lever on „I“: 

 

Secondary air slide valve completely open / 

 

Primary air slide valve completely closed

 

Operating lever on „II“

 

Secondary air slide valve completely open / 

 

Primary air slide valve completely open

Regulation of combustion air

Position of operating lever:
„II”
 ..... Ignition position, max. heat output
„I“ ....... Nominal heat output with billet wood
„I“ ....... Nominal heat output with wood briquettes
„0“ ..... Obtain glow

 

As the secondary air also contributes to the cleanliness 

of the glass pane, the operating lever should be set on 

“I” minimum. This also applies in the event of low-load 

operation.

 

When not operating the lever should be set on “0”, to re-

duce the cooling down of the room.

Fire grate

Operating lever for the fire grate

 

With the help of the operating lever the fire grate can 

be opened or closed to move the ash from the combus-

tion chamber to the ash pan by pushing the fire grate 

back and forth.

 

Primary air can only enter the combustion chamber if 

the fire grate is set on open position.

Wood storage compartment

press here

The wood storage compartment below the combustion 

chamber is fitted with a magnetic pressure closure. It can 

be opened by lightly pressing on the button (Olsberg 

logo). Likewise it can be closed by lightly pressing.

19

Cleaning

What?

How often?

Using what?

inside of stove

at least 1 x per year

hand brush,

vacuum cleaner

connection piece

at least 1 x per year

hand brush,

vacuum cleaner

glass panel

as required

when cold

using glass cleaner for

stoves- and oven glasses

painted surfaces

as required

when cold

with a slightly damp microfibre cloth

Measuring negative pressure 

in the combustion chamber

Above the combustion chamber opening, behind the up-

per door, there is a measuring duct on which the negative 

pressure in the combustion chamber can be measured 

with the door closed during heating operation.

 

measuring duct

Replacement parts

Attention:

Please ask your specialist trader for any replacement parts 

required. Always use original spare parts only. We guaran-

tee a ten-year availability of spare parts.

In order to process your order as quickly as possible, it is 

imperative that you send us the type and fabrication num-

ber given on the stove’s rating plate.

The stove identification plate is situated in the wood stor-

ing compartment.

We recommend the relevant numbers here before install-

ing the stove to ensure that you always have them to hand:

Type number: 23/__________

Fabrication number: __________________________

Summary of Contents for PENMAN PULAR

Page 1: ...INSTRUCTION MANUAL OLSBERG PULAR COMPACT DIN EN 13240 DIN 18897 raumluftunabh ngig DIBt Bauaufsichtliche Zulassung 15a BV G INSTALLATION INSTRUCTIONS OLSBERG PULAR CYLINDRICAL STOVE...

Page 2: ...PAGE 2...

Page 3: ...10 3 1 General Information 3 2 Suitable Fuels 3 3 Reducing Emissions 3 4 Lighting the for the first time 3 5 After Use Maintining the perfect burn 3 6 Operating The Air Slide Valve 3 7 Operating the...

Page 4: ...e the rest of the fuel burns up in the second phase of the combustion process This process is characterized by strongly glowing embers with no or only smaller temporary flames Optimal and environmenta...

Page 5: ...Pa can lead to uncontrollable combustion process that can damage the appliance itself the connecting pipe and the chimney sweep or a competent expert about finding a solution In such cases we recommen...

Page 6: ...ch its surface to prevent damage of lacquering Use protective gloves for your own protection and for the sake of the intactness of the lacquering The doors of the stove should be kept slightly open du...

Page 7: ...ditions Authorization of the stove as independent of the air in the room and insulated air inlet from outside are among these conditions It is important to consult a competent chimney sweep or expert...

Page 8: ...eeve and the sealing cover Decide where the stove is to be installed There must be no objects made of combustible materials within a dis tance of 80 cm of the stove s radiation area measured from the...

Page 9: ...horizontal connecting valves Incase of stoves with a capacity of 6kW the minimum length of the vertical connecting pipe is 50cm We recommend the use of an insert with a double wall for connecting to t...

Page 10: ...uel according to heat demand The heating value of 1kg of dry wood is 4 4 5kW This means you can place about 2 4kg of wood into a stove of 8kW capacity every hour When burning wood if a lower capacity...

Page 11: ...ant to load more fuel and only if the previous amount has burned down to embers The condition of proper operation of the stove is the appropriate chimney draught feed pressure This is considerably dep...

Page 12: ...g lever for the fire grate With the help of the operating lever the fire grate can be opened or closed to move the ash from the combus tion chamber to the ash pan by pushing the fire grate back and fo...

Page 13: ...Regulation of combustion air Position of operating lever II Ignition position max heat output I Nominal heat output with billet wood I Nominal heat output with wood briquettes 0 Obtain glow As the se...

Page 14: ...Use only a small amount of fuel at first Use only a small amount of fuel when reloading Riddle Grate What are the causes There is no proper draught at heating up Chimney or stove pipe is not closed pr...

Page 15: ...re made of materials of excellent quality There s continuous control through the manufacturing procedures and the finished stove is subjected to stringent quality control 5 0 SPECIAL NOTES WHAT FREQUE...

Page 16: ...PAGE 16 APPENDIX 1 DIMENSIONAL DRAWINGS 147 147 1218 472 472...

Page 17: ...PAGE 17 BLANK...

Page 18: ...PAGE 18 BLANK...

Page 19: ......

Page 20: ...Brought to you by Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN Tel 01204 868 550 Fax 01204 868 551 Email sales percydoughty com www visionfires co uk...

Reviews: