3.8 - Regulation of Combustion Air
On the Combustion lever, shown in Fig. A, each marker is an individual setting, as shown below:
• II ..... Ignition position, max. heat output
• I....... Nominal heat output with billet wood
• I....... Nominal heat output with wood briquettes
• 0 ..... Obtain glow
As the secondary air also contributes to the cleanliness of the glass pane, the operating lever should be set
on “I” minimum. This also applies in the event of low-load operation. When not in use the lever should be
set on“0”, to reduce the cooling down of the room.
3.0 OPERATING INSTRUCTIONS
3.9 - Using the Wood Storage Compartment
The wood storage compartment below the combustion chamber
is fitted with a magnetic pressure closure. It can be opened by
lightly pressing on the button (Olsberg logo). Likewise it can be
closed by lightly pressing.
4.0 - Measuring Negative Pressure
Above the combustion chamber opening, behind the upper
door, there is a measuring duct on which the negative pressure
in the combustion chamber can be measured with the door
closed during heating operation.
17
Combustion air slide valve
Operating lever for combustion air supply
●
Operating lever on „0“:
all slide valves closed
●
Operating lever on „I“:
Secondary air slide valve completely open /
Primary air slide valve completely closed
●
Operating lever on „II“:
Secondary air slide valve completely open /
Primary air slide valve completely open
Regulation of combustion air
Position of operating lever:
„II” ..... Ignition position, max. heat output
„I“ ....... Nominal heat output with billet wood
„I“ ....... Nominal heat output with wood briquettes
„0“ ..... Obtain glow
●
As the secondary air also contributes to the cleanliness
of the glass pane, the operating lever should be set on
“I” minimum. This also applies in the event of low-load
operation.
●
When not operating the lever should be set on “0”, to re-
duce the cooling down of the room.
Fire grate
Operating lever for the fire grate
●
With the help of the operating lever the fire grate can
be opened or closed to move the ash from the combus-
tion chamber to the ash pan by pushing the fire grate
back and forth.
●
Primary air can only enter the combustion chamber if
the fire grate is set on open position.
Wood storage compartment
press here
The wood storage compartment below the combustion
chamber is fitted with a magnetic pressure closure. It can
be opened by lightly pressing on the button (Olsberg
logo). Likewise it can be closed by lightly pressing.
19
Cleaning
What?
How often?
Using what?
inside of stove
at least 1 x per year
hand brush,
vacuum cleaner
connection piece
at least 1 x per year
hand brush,
vacuum cleaner
glass panel
as required
when cold
using glass cleaner for
stoves- and oven glasses
painted surfaces
as required
when cold
with a slightly damp microfibre cloth
Measuring negative pressure
in the combustion chamber
Above the combustion chamber opening, behind the up-
per door, there is a measuring duct on which the negative
pressure in the combustion chamber can be measured
with the door closed during heating operation.
measuring duct
Replacement parts
Attention:
Please ask your specialist trader for any replacement parts
required. Always use original spare parts only. We guaran-
tee a ten-year availability of spare parts.
In order to process your order as quickly as possible, it is
imperative that you send us the type and fabrication num-
ber given on the stove’s rating plate.
The stove identification plate is situated in the wood stor-
ing compartment.
We recommend the relevant numbers here before install-
ing the stove to ensure that you always have them to hand:
Type number: 23/__________
Fabrication number: __________________________
Summary of Contents for PENMAN PULAR
Page 2: ...PAGE 2...
Page 16: ...PAGE 16 APPENDIX 1 DIMENSIONAL DRAWINGS 147 147 1218 472 472...
Page 17: ...PAGE 17 BLANK...
Page 18: ...PAGE 18 BLANK...
Page 19: ......