- 27 -
This is an infrared remote control.
You must therefore
point it at the receiver unit on the back of the unit to
operate it.
If the reception is not optimum, then please change
the position of the receiver from horizontal to vertical.
Make sure that the sensor points to the centre of the
room.
The following unit settings can be made with the re-
mote control:
•
Start ignition process
•
Switch off
•
Change heating power setting
P
•
Change convection fan setting
V
The change to the heating power and convection fan
setting will be indicated by means of an acoustic
signal.
If level
A
is selected (= Automatic), the signal
sounds 3x.
The control lamp of the remote control flashes when
the buttons are pressed.
Ignition
Press buttons
1 a
nd
3
at the same time.
Switch off
Press buttons
2 a
nd
4
at the same time.
Change heating power
Press one or both of the buttons that are marked
with a flame.
Increase
1
Decrease
2
.
Change convection fan speed
Press one or both of the buttons that are marked
with a fan in order to change the speed of the
room fan.
Increase
3
Decrease
4.
14. Alarm messages
Any operational faults are shown in the display by
means of alarm messages. In addition, an acoustic
signal sounds.
The pellet feed is cut off, and the flue gas and con-
vection air fan continue running for a maximum of 20
minutes.
14.1. Resetting the alarm message
After the cause of the fault has been eliminated, the
alarm message in the display can be reset as follows:
•
Wait until the unit has cooled down completely.
•
Press the
OFF
button for 5 seconds to reset the
alarm message.
•
The message
FINAL CLEANING
appears
•
If necessary, remove any combustion residue
from the combustion chamber.
•
Reset the
FINAL CLEANING
message with
OFF
.
•
Restart the unit.
If the error message appears again immediately, then
contact your dealer to eliminate the cause.
14.2. Alarm SMOKE TEMP.
This occurs if the flue gas temperature is not ade-
quate for safe operation of the unit.
Possible causes:
•
No more pellets in the storage container
•
The quality of the pellets is inadequate (e.g.
damp)
•
The rate of delivery of the pellets is too low in the
lowest power setting.
•
The combustion pan is slagged.
•
The chimney draft is too high or too low.