- 20 -
7. Assembly instructions
•
Determine the exact installation location. No
flammable objects or materials may be posi-
tioned or stored within the radiance range, i.e. a
distance of 80 cm from the viewing glass of the
chimney stove.
Minimum distance between the unit and
flammable or supporting walls:
A = adjacent wall
B = back wall
C = side wall
D = floor protection
•
Install the pipe lining (on-site) into the chimney.
The height of connection can be determined indi-
vidually, but should not exceed 1.5 m from the
connector fittings. In the case of inserting through
flammable material, no flammable materials
should be found within a radius of 20 cm of the
stove pipe.
•
Connect the stove pipe (on-site) to the D=Ø80
mm connector fittings of the chimney stove.
•
Slide the chimney stove on the intended installa-
tion site and align it so that the stove pipe fits into
the pipe lining.
Important:
•
The stove pipe connections must be sealed tight
and leak-proof.
We recommend the use of Olsberg stove pipes
with a sealing lip.
•
In order to clean the connection pipes, arcs with
cleaning openings must be used.
•
The stove pipe may not extend into the chimney.
•
Please remember that the surrounding walls and
installation base may reach a temperature of up
to 85°C according to the test regulation EN
13240, and this may cause discolouration to
wallpaper, floor coverings such as cork or similar
construction materials.
8.
Start-up and operation
•
The pellet-burning chimney stove is connected
by the attachment plug found on the unit to a
220V power socket, which is protected by a cir-
cuit breaker.
•
Switch the main switch on the back side of the
unit to "I".
•
An acoustical signal is sounded and the display
is activated.
•
Fill the pellet container with pellets.
•
The operator language under point 10.4.3 select
8.1 Permissible fuels
•
The pellet-buring chimney stove may only be
fueled with pellets that correspond to the certifi-
cation program DINplus or Austrian Norm M
7135.
Max. thickness = 7 mm
Max. length = 30mm
Max. moisture content 10%
•
The pellets must be stored in a dry and dust-free
environment.
•
When filling the pellets, please take care that the
pellet container of the unit is not filled with poten-
tially accumulated sawdust.
8.2 Please note before the first
heating
•
Ensure that all accessories are removed from the
ash collection tray and the combustion chamber.
•
The odour caused by the vapourising of the pro-
tective coating will disappear after the chimney
stove has been burning for several hours (venti-
late the room well).