Leveling Table Insert
Adjust the table insert flush with the table by
turning the four leveling screws (C, Figure 16).
Place a straight edge across the table and
insert. Raise the insert until it just touches the
straight edge. Check both the front and rear
section of the insert.
Splitter and Blade Guard Assembly
1. Disconnect saw from power source.
2. Remove table insert by loosening the screw
at the front of insert. Pull up and towards
you to release the rear clip.
3. Insert the blade guard shaft (D, Figure 17)
into rear trunion through opening at rear of
saw.
4. Lock the shaft into place by turning the bolt
(A, Figure 18) until it secures the shaft, then
tighten the bolt with the jam nut (B).
5. Place bracket assembly (E, Figure 17) on to
the shaft and thread a hex head bolt and a
lock washer (F, Figure 17) into the bracket.
6. Thread the guard support assembly (G,
Figure 17) into the bracket.
7. Insert front fork of blade guard assembly (A,
Figure 19) through opening in the table. The
tab is held in place between the flat washer
and bracket, see Figure 19. Finger tighten
hex nut (B, Figure 19) only at this time.
8. Insert the rear fork of the blade guard
assembly (C, Figure 19) into the guard
support assembly between the flat
washer and shoulder, see Figure 19.
Finger tighten hex nut (D, Figure 19)
only at this time.