Installation
19
5.8.3
Bonding terminal
The appliance must be connected to an equipotential bonding system. For this purpose use
the connection terminal marked "equipotential" located on the left hand side underneath
the appliance in the vicinity of the various connection points (see Figure 7).
Fig. 7
34.
Front left foot
35.
Chassis
36.
Equipotential (bonding) terminal
5.9
Water connection
The water connection must be made using a flexible or rigid metal pipe with an adequate
diameter.
5.10
Drain connection
The appliance must be connected to a floor drain. The drain connection must be made with
a heat resistant (at least 90 °C) plastic pipe. The connection to the drainage system must
be made in conformity with the local hygiene regulations in force.
5.11
Staff training
Instruct personnel in the use of this appliance by referring to the user handbook and supply
them with copies of the handbook.