ISS0011R10_A_EN.doc
10.
DISPLAY INDICATIONS
DESCRIPTION
GREEN LED
YELLOW LED
GREEN LED
RED LED
Standby
ON
Machine on
ON
Timer(s) on
ON
ON
Automatic operation
ON
ON
Malfunctions
“Dirty filter” malfunction
ON L*
‘Probe KO’ malfunction
ON L*
ON L*
ON L*
SELF-TEST operation
ON L*
ON L*
ON L*
ON L*
*) ON L = blinks for 1 second ON, 1 sec. OFF.
WIRING DIAGRAM
A1 Electronic power board
A2 Electronic command board
B1 Thermostat probe
F1
Compressor thermal protection
K1 Relay for compressor
K2 Relay for fan (MED)
K3 Relay for fan (MAX)
K4 Relay for fan (MIN)
M1 Compressor
M2 Fan
M3 Condensate discharge pump
S1
Safety micro switch
S2
Pump micro switch
T1
Transformer
X1 General power supply terminal board
X2 4-pole connector
X3 9-pole connector
X4 6-pole connector
X5 8-pole connector
Z1
Compressor condenser
Z2
Fan condenser
Summary of Contents for ISSIMO 11